排序方式: 共有22条查询结果,搜索用时 31 毫秒
1.
Electron cyclotron emission imaging system in the frequency range of 95 GHz -125 GHz is going to be constructed for a two-dimensional diagnosis of the electron temperature profiles and fluctuations on the HT-7 Tokamak. The optical design for the ECEI diagnostic system is completed. Because of the superconducting technology used in HT-7, the vacuum chamber is rather thick (630 mm), the height of the horizontal windows is limited (maximum 450 mm), which constrains greatly the ECE imaging Gaussian beam that passing through the windows. We here comes to make a design compromise between the number of the beams that can pass through the windows and the spatial resolution (around 1.1 cm). We also find that due to the field curvature of the optical system, the gaussian beams of edge channels are always overlapped. To flatten the field curvature, it is needed to insert a concave made of a material with a low refractive index (compared with the one used in the convex). But the suitable material has not been avail 相似文献
2.
The evolutions of the electron temperatures of Muminum plasmas produced with 0.351 μm laser are simulated by means of one-dimensional hydrodynamic code. The simulations show that the plasma geometry has strong influence on the electron temperature's evolution while the effect of the flux limiter is not so significant. The simulations are in good agreement with the experiments only at some spatial points. A full comparison between the simulations and experiments indicates that the one-dimensional code is not accurate enough to characterize the laser-produced plasmas. A post-processor code based on the hydro code is developed to generate the streak image of the Thomson scattering spectra, which can be directly compared with the experimental data. 相似文献
3.
4.
1.IntroductionPenningtrapshavebeenwidelyusedtotrapchargedparticles,suchaselectronsorions,forstudyonthefundamentalpropertiesofparticles,andthetransportandequilibriumpropertiesofnon--neutralplasmas[1-4].InaPenningtrap,auniformaxialmagneticfieldprovidesradialconfinement,whiletheelectricfieldbetweentheelectrodesprovidesaxialone.Thetrapcanconfineasmallnumberofchargedparticlesforverylongtime.However,becauseoftheself-electricfieldeffect,themaximumdensityofnonneutralplasma(electron)radicallyconfinedb… 相似文献
5.
In this article, the design idea of a 57-pin Langmuir probe array is presented, together with some experimental results. The manufacture technique of the probe array is discussed. Two-dimensional distributions of the plasma density, the floating potential and their fluctuations in the poloidal cross section are obtained. The blobs, which move radially and poloidally, cause great particle and energy transport. The charge neutralization by the poloidal movement of particles greatly decreases the vertical electric field in the helimak plasma. This leads to a confinement time which is two orders of magnitude larger than the theoretical prediction. 相似文献
6.
7.
Steady-state plasma generated by electron cyclotron resonance (ECR) wave in the KT5D magnetized torus was studied using a fast high-resolution camera and Langmuir probes. It was found that both the discharge patterns taken by the camera and the plasma parameters measured by the probes were very sensitive to the working gas pressure and the magnetic configuration of the torus both without and with vertical fields. There existed fast vertical motion of the plasma. Tentative discussion is presented about the observed phenomena such as the bright resonance layer at a high gas pressure and the wave absorption mechanism at a low pressure. Further explanations should be found. 相似文献
8.
At the first stage of the electron cyclotron emission imaging (ECEI) diagnostic project on HT-7, a 16-channel vertical-resolved ECEI diagnostic has been developed and installed on HT-7 tokamak to measure electron cyclotron emission with a temporal resolution of 0.5 usec. The system works at a fixed frequency of 97.5 GHz. The sample volumes of the system are aligned vertically with a vertical channel spacing of 11 mm, and can be shifted across the plasma cross-section by varying the toroidal magnetic field. The high spatial resolution of the system is achieved by utilizing a low-cost linear mixer/receiver array and an optical imaging system. The focus location may be shifted horizontally when translating one of the optical imaging elements. The details of the system design and laboratory testing of the ECEI optics are presented together with the preliminary experimental results. 相似文献
9.
1 IntroductionThe light imaging is a very useful tool in monitor-ing plasma discharges with real two dimensional reso-lution, comparing with many commonly used diagnos-tic techniques such as various Langmuir probes, whichmay have good spatial resolution based on point topoint measurements, or chord to chord measurements.TV camera with CCD sensor is one of the imagingtools being used [1~5], however conventional TV cam-eras are usually difficult to program and with ratherlow temporal (typicall… 相似文献
10.
Electron cyclotron emission imaging system in the frequency range of 95 GHz ~125 GHz is going to be constructed for a two-dimensional diagnosis of the electron temperature profiles and fluctuations on the HT-7 Tokamak. The optical design for the ECEI diagnostic system is completed. Because of the superconducting technology used in HT-7, the vacuum chamber is rather thick (630 mm), the height of the horizontal windows is limited (maximum 450 mm), which constrains greatly the ECE imaging Gaussian beam that passing through the windows. We here comes to make a design compromise between the number of the beams that can pass through the windows and the spatial resolution (around 1.1 cm). We also find that due to the field curvature of the optical system, the gaussian beams of edge channels are always overlapped. To flatten the field curvature, it is needed to insert a concave made of a material with a low refractive index (compared with the one used in the convex). But the suitable material has not been available so far, therefore the deterioration of the resolution in some channels (e.g. the edge channels) is acceptable. 相似文献