排序方式: 共有6条查询结果,搜索用时 15 毫秒
1
1.
2.
3.
本文报导了一个大体积混合多多会切点负离子源的电子和负离子的密度和温度。基于定标律做了等离子 的形成和损失过程的分析。分析表明,正离子到壁上的损失是主要的,尽管注意到定标律是n+∞I^0.57d。然而,总的等离子体的损失与放电电流成线性关系,同理论模型吻合。 相似文献
4.
HL-2A中性束注入器送气实验 总被引:1,自引:1,他引:0
为满足HL-2A中性束加热的需求,我们为HL-2A的NBI注入器研制了脉冲送气回路及其控制系统,系统的核心流量控制部件为PEV-1压电晶体阀,主要是根据气压测量结果调整压电阀电源输出脉冲电压波形来控制压电阀的流导.为克服了压电阀性能参数离散,对不同离子源的送气回路进行了单独标定.送气实验结果表明,离子源放电室气压控制精度达到了0.05Pa,通过调整不同压电阀电源输出波形,减小了束线4个离子源送气回路之间相互影响,得到了平稳的离子源工作气压. 相似文献
5.
During the operation of a high-power neutral beam injection(NBI)system on the HL-1M tokamak,an optical diagnostic means using CCD camera was developed to characterize the NBI performance.The vacuum valve opening process and NBI period in the HL-1M experiment were displayed by a lot of photos taken with this means.Thus,the Hα emission profiles of the neutral beam(NB) and its interaction with plasma were given.Finally,the reason possible for plasma breakdown during NB1 model II discharge was investigated.this in-situ diagnosis can provide more information of the NB1. 相似文献
6.
1