1.
A low-noise readout integrated circuit for high-energy particle detector is presented.The noise of charge sensitive amplifier was suppressed by using single-side amplifier and resistors as source degeneration.Continuous-time semi-Gaussian filter is chosen to avoid switch noise.The peaking time of pulse shaper and the gain can be programmed to satisfy multi-application.The readout integrated circuit has been designed and fabricated using a 0.35 μm double-poly triple-metal CMOS technology.Test results show the functions of the readout integrated circuit are correct.The equivalent noise charge with no detector connected is 500–700 e in the typical mode,the gain is tunable within 13–130 mV/fC and the peaking time varies from 0.7 to 1.6 μs,in which the average gain is about 20.5 mV/fC,and the linearity reaches 99.2%.  相似文献   