首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
轻工业   1篇
原子能技术   3篇
自动化技术   2篇
  2007年   2篇
  2006年   1篇
  2004年   1篇
  2003年   1篇
  1969年   1篇
排序方式: 共有6条查询结果,搜索用时 15 毫秒
1
1.
Abstract— We report on theoretical simulations and measurements of the optics of BiNem® displays, taking into account not only the luminance at normal incidence, but contrast ratio and color shift over the viewing hemisphere as well. Transmissive and reflective BiNem® modes were optimized differently, emphasizing contrast in transmission and paperlike, white appearance in reflection.  相似文献   
2.
The effects of neutron irradiation on the mechanical properties of welded joints made of austenitic stainless steels have been investigated. The materials are welded AISI 304 and AISI 347, so-called test weld materials, irradiated with neutrons at 573 K to doses of 0.3 and 1.0 dpa. In addition, an AISI 304 from a decommissioned pressurised water reactor, so-called in-service material, which had accumulated a maximum dose of 0.35 dpa at about 573 K, was investigated. The mechanical properties of heat-affected zones and base materials were analysed before and after irradiation. Tensile parameters were determined at room temperature and at 573 K, for all materials and irradiation conditions. In the test weld materials it is found that radiation hardening is lower and loss of ductility is higher in the heat-affected zone than in the base material. In the in-service material radiation hardening is about the same in heat-affected zone and base material. After irradiation, deformation takes place by stacking faults and twins, at both room temperature and high temperature, contrary to unirradiated materials, where deformation takes place by twinning at room temperature and by dislocation cells at high temperature. No defect free channels are observed.  相似文献   
3.
Abstract— Bistable liquid‐crystal displays have been developed by using BiNem® technology. In this paper, the BiNem® principle, addressing, power consumption, reflective mode, and manufacturing process will be described, and performance of the latest displays will be discussed. We will show that this technology has simultaneously low power consumption due to bistability, very good visual quality, passive‐addressing mode, and a manufacturing process compatible with STN mass‐production equipment.  相似文献   
4.
The paper describes the construction of a magnetic electron analyzer for pulsed beam electron energy distribution studies. The single shot information is obtained using a NMOS linear image sensor. Both the energetical and the sensitivity calibration were performed using careful numerical simulations. For simplicity, the signals can be read on an oscilloscope, and they are transmitted via an optic fiber, which allows the analyzer to work while connected to high voltage. The analyzer was successfully implemented on a 15 kV/3 kJ plasma focus device and was used to study the electron energy distribution in the 30–660 keV range..  相似文献   
5.
The effects of neutron irradiation on the microstructure of welded joints made of austenitic stainless steels have been investigated. The materials were welded AISI 304 and AISI 347, so-called test weld materials, and irradiated with neutrons at 300 °C to 0.3 and 1.0 dpa. In addition, an AISI 304 type from a decommissioned pressurised water reactor, so-called in-service material, which had accumulated a maximum dose of 0.35 dpa at about 300 °C, was investigated. The microstructure of heat-affected zones and base materials was analysed before and after irradiation, using transmission electron microscopy. Neutron diffraction was performed for internal stress measurements. It was found that the heat-affected zone contains, relative to the base material, a higher dislocation density, which relates well to a higher residual stress level and, after irradiation, a higher irradiation-induced defect density. In both materials, the irradiation-induced defects are of the same type, consisting in black dots and Frank dislocation loops. Careful analysis of the irradiation-induced defect contrast was performed and it is explained why no stacking fault tetrahedra could be identified.  相似文献   
6.
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号