首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   21篇
  免费   2篇
化学工业   2篇
建筑科学   1篇
轻工业   2篇
无线电   3篇
冶金工业   8篇
自动化技术   7篇
  2020年   2篇
  2016年   2篇
  2015年   1篇
  2011年   1篇
  2009年   1篇
  2008年   1篇
  2007年   1篇
  2006年   2篇
  2005年   1篇
  2001年   1篇
  1998年   3篇
  1997年   2篇
  1996年   1篇
  1995年   1篇
  1977年   1篇
  1976年   2篇
排序方式: 共有23条查询结果,搜索用时 15 毫秒
1.
The Dynamic Reference (DR) method has been developed for subjective image quality experiments in which original or undistorted images are unavailable. The DR method creates reference image series from test images. Reference images are presented to observers as a slide show prior to evaluating their quality. As the observers view the set of reference images, they determine the overall variation in quality within the set of test images. This study compared the performance of the DR method to that of the standardized absolute category rating (ACR) and paired comparison (PC) methods. We measured the performance of each method in terms of time effort and discriminability. The results showed that the DR method is faster than the PC method and more accurate than the ACR method. The DR method is especially suitable for experiments that require highly accurate results in a short time.  相似文献   
2.
3.
OBJECTIVES: Fructose-1,6-diphosphate is a glycolytic intermediate that has been shown experimentally to cross the cell membrane and lead to increased glycolytic flux. Because glycolysis is an important energy source for myocardium during early reperfusion, we sought to determine the effects of fructose-1,6-diphosphate on recovery of postischemic contractile function. METHODS: Langendorff-perfused rabbit hearts were infused with fructose-1,6-diphosphate (5 and 10 mmol/L, n = 5 per group) in a nonischemic model. In a second group of hearts subjected to 35 minutes of ischemia at 37 degrees C followed by reperfusion (n = 6 per group), a 5 mmol/L concentration of fructose-1,6-diphosphate was infused during the first 30 minutes of reperfusion. We measured contractile function, glucose uptake, lactate production, and adenosine triphosphate and phosphocreatine levels by phosphorus 31-nuclear magnetic resonance spectroscopy. RESULTS: In the nonischemic hearts, fructose-1,6-diphosphate resulted in a dose-dependent increase in glucose uptake, adenosine triphosphate, phosphocreatine, and inorganic phosphate levels. During the infusion of fructose-1,6-diphosphate, developed pressure and extracellular calcium levels decreased. Developed pressure was restored to near control values by normalizing extracellular calcium. In the ischemia/reperfusion model, after 60 minutes of reperfusion the hearts that received fructose-1,6-diphosphate during the first 30 minutes of reperfusion had higher developed pressures (83 +/- 2 vs 70 +/- 4 mm Hg, p < 0.05), lower diastolic pressures (7 +/- 1 vs 12 +/- 2 mm Hg, p < 0.05), and higher phosphocreatine levels than control untreated hearts. Glucose uptake was also greater after ischemia in the hearts treated with fructose-1,6-diphosphate. CONCLUSIONS: We conclude that fructose-1,6-diphosphate, when given during early reperfusion, significantly improves recovery of both diastolic and systolic function in association with increased glucose uptake and higher phosphocreatine levels during reperfusion.  相似文献   
4.
Gastric biopsy specimens of 57 consecutively observed dyspeptic patients were studied for the presence of Helicobacter pylori by histological examination, biopsy urease test (BUT) and culture. For culture, biopsy samples were transported in both Stuart media and BUT tubes. All 15 isolates could be cultured from both Stuart and BUT tubes. Thus, if the main reason for culture of Helicobacter pylori is for antimicrobial susceptibility testing, only positive BUT tubes need to be submitted. This would reduce both the expense and the number of biopsies needed.  相似文献   
5.
The problem of identifying clusters from MIMO measurement data is addressed. Conventionally, visual inspection has been used for cluster identification, but this approach is impractical for a large amount of measurement data. For automatic clustering, the multipath component distance (MCD) is used to calculate the distance between individual multipath components estimated by a channel parameter estimator, such as SAGE. This distance is implemented in the well-known KMeans clustering algorithm. To demonstrate the effectiveness of the choice made, the performance of the MCD and the Euclidean distance were compared by clustering synthetic data generated by the 3GPP spatial channel model (SCM). Using the MCD significantly improved clustering performance  相似文献   
6.
An open-ended coaxial probe designed to measure layered biological media is analyzed with a new method. The probe is considered as an electrostatic circuit element whose capacitance is solved using a stationary functional. The fundamental transverse electric and magnetic field (TEM)-mode and the series of evanescent wavemodes in the coaxial cable are used as basis functions. The field outside the probe is solved using a Hankel transform. The capacitance is calculated for homogeneous materials and two-layer structures and the results are compared with values measured with a phantom model. The method can be easily extended for structures with an arbitrary number of layers. A practical approximation for two-layer cases, originally developed to take into account the effect of subcutaneous fat in skin measurements, is presented and its validity for different combinations of dielectric constants and the thickness of the first layer is demonstrated. The static approximation limits the frequency range, but it covers biological measurements up to 500 MHz. The developed method is accurate and easy to adopt in practice  相似文献   
7.
A high-performance liquid chromatographic (HPLC) procedure for quantitating ketoprofen in isopropyl myristate (IPM), a compound widely used as a receptor medium in drug diffusion studies of topical aqueous-based formulations, is developed. Previously reported HPLC assays for ketoprofen in IPM have employed relatively complex and tedious methods for purifying the IPM prior to injection onto the HPLC column. The present assay method utilizes a direct injection of the IPM-based sample onto a new reversed-phase ODS column and employs ultraviolet detection at 265 nm. Propyl paraben is employed as the internal standard. The mobile phase consists of acetonitrile-methanol-water (36:54:10, v/v/v) at a flow rate of 1.2 mL/min. The calibration curves are linear (correlation coefficient r > or = 0.988) over concentration ranges of 0.625-10 micrograms/mL and 6.25-100 micrograms/mL. The within-day and between-day precision exhibit coefficients of variation of 1.3-3.3%, and the accuracy (reported as relative error of the mean) varies from -1.9% to 0.6%. The retention times for ketoprofen and propyl paraben are approximately 2.3 and 3.3 min, respectively. The total run time per sample is approximately 7 min. The minimum quantitatable concentration is approximately 0.625 microgram/mL. The assay is stability-indicating, rapid, reproducible, sensitive, and readily adaptable for assaying other non-steroidal anti-inflammatory drugs.  相似文献   
8.
This article discusses how shifting the focus of research to the emotional side of human actions and cognition could create new perspectives on the problem of how to support the human operator in the control of rare disturbances. A new construct, Expert Identity, is described. A qualitative study of the specific problems with changing the operator generation at a nuclear power plant is presented. The results indicate that the current identity of the trainees is more or less still one of the trainees. The conceived demands of operator work and the perceived learning opportunities are characterised by a dichotomy: disturbances or other exceptional situations emerge as different from daily work. The key challenge and motive for the trainees in the development of expertise is to achieve not only an adequate degree of competence but also to construct confidence in being able to cope with potential disturbance situations.
Maaria NuutinenEmail:
  相似文献   
9.
Wavelet-based reconstruction for limited-angle X-ray tomography   总被引:1,自引:0,他引:1  
The aim of X-ray tomography is to reconstruct an unknown physical body from a collection of projection images. When the projection images are only available from a limited angle of view, the reconstruction problem is a severely ill-posed inverse problem. Statistical inversion allows stable solution of the limited-angle tomography problem by complementing the measurement data by a priori information. In this work, the unknown attenuation distribution inside the body is represented as a wavelet expansion, and a Besov space prior distribution together with positivity constraint is used. The wavelet expansion is thresholded before reconstruction to reduce the dimension of the computational problem. Feasibility of the method is demonstrated by numerical examples using in vitro data from mammography and dental radiology.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号