全文获取类型
收费全文 | 39篇 |
免费 | 1篇 |
专业分类
化学工业 | 5篇 |
机械仪表 | 3篇 |
建筑科学 | 1篇 |
能源动力 | 1篇 |
轻工业 | 2篇 |
水利工程 | 2篇 |
石油天然气 | 1篇 |
无线电 | 11篇 |
一般工业技术 | 7篇 |
冶金工业 | 6篇 |
自动化技术 | 1篇 |
出版年
2022年 | 1篇 |
2020年 | 1篇 |
2018年 | 1篇 |
2017年 | 1篇 |
2016年 | 1篇 |
2015年 | 1篇 |
2014年 | 1篇 |
2013年 | 2篇 |
2012年 | 1篇 |
2011年 | 3篇 |
2009年 | 1篇 |
2008年 | 2篇 |
2007年 | 3篇 |
2006年 | 1篇 |
2005年 | 1篇 |
2003年 | 1篇 |
2002年 | 5篇 |
2001年 | 1篇 |
2000年 | 1篇 |
1998年 | 4篇 |
1997年 | 1篇 |
1996年 | 2篇 |
1994年 | 1篇 |
1990年 | 2篇 |
1989年 | 1篇 |
排序方式: 共有40条查询结果,搜索用时 6 毫秒
1.
Fantuzzi E Morelli B Falangi G Patrizii L Togo V 《Radiation protection dosimetry》2002,101(1-4):573-578
The ENEA fast neutron dosemeter is based on a planar PADC (poly allyl diglycol carbonate) placed in a polyethylene holder. The CR-39 (registered trademark of PPG Industries Inc.) material, produced by Intercast Europe S.p.A., has been used in the routine of the Individual Monitoring Service (IMS) since 1998. Since then, acceptance tests on average sheet background track density and sheet neutron sensitivity have been made on new batches as a quality control within a quality assurance programme of the IMS of ENEA-Institute for Radiation Protection (IRP). Dosemeters were irradiated with a 241Am-Be source at ENEA-IRP and processed through a chemical etching procedure (pre-etching with 40% KOH water solution 6.25 N and 60% ethyl alcohol at 70 degrees C followed by 12 h of etching in 6.25 N KOH water solution). In this paper we present the analysis of acceptance testing data for more than 30 sheets of CR-39 plastic produced in 1998, 1999 and 2000. Moreover, we compare the performance of sheets of CR-39 of standard composition with that of sheets of CR-39 with the addition of DOP (dioctylphthalate), in different concentrations, on the hasis of average background density, neutron sensitivity and background fluctuation that limit the lower detectable dose. This study demonstrates the need for acceptance tests to assure the quality of the dosimetric performance of these dosemeters, which is considerably dependent on the quality of the CR-39 plastic. 相似文献
2.
Makoto Togo Akimasa TakamuraTatsuya Asai Hirokazu KajiMatsuhiko Nishizawa 《Journal of power sources》2008
An enzyme-based glucose/O2 biofuel cell was constructed within a microfluidic channel to study the influence of electrode configuration and fluidic channel height on cell performance. The cell was composed of a bilirubin oxidase (BOD)-adsorbed O2 cathode and a glucose anode prepared by co-immobilization of glucose dehydrogenase (GDH), diaphorase (Dp) and VK3-pendant poly-l-lysine. The consumption of O2 at the upstream cathode protected the downstream anode from interfering O2 molecules, and consequently improved the cell performance (maximum cell current) ca. 10% for the present cell. The cell performance was also affected by the channel height. The output current and power of a 0.1 mm-height cell was significantly less than those of a 1 mm-height cell because of the depletion of O2, as determined by the shape of the E–I curve at the cathode. On the other hand, the volume density of current and power was several times higher for the narrower cell. 相似文献
3.
V. N. Bukhartsev A. Yu. Ivanov I. Togo 《Power Technology and Engineering (formerly Hydrotechnical Construction)》1990,24(4):281-284
Translated from Gidrotekhnicheskoe Stroitel'stvo, No. 4, pp. 46–48, April, 1990. 相似文献
4.
Togo M. Watanabe K. Yamamoto T. Ikarashi N. Tatsumi T. Ono H. Mogami T. 《Electron Devices, IEEE Transactions on》2002,49(11):1903-1909
We have developed a low-leakage and highly reliable 1.5-nm SiON gate-dielectric by using radical oxygen and nitrogen. In this development, we introduce a new method for determining an ultrathin SiON gate-dielectric thickness based on the threshold voltage dependence on the substrate bias in MOSFETs. It was found that oxidation using radical oxygen followed by nitridation using radical nitrogen provides the 1.5-nm (oxide equivalent thickness) SiON, in which leakage current is two orders of magnitude less than that of 1.5-nm SiO/sub 2/ without degrading device performance in NMOSFETs. The 1.5-nm (oxide equivalent thickness) SiON was also found to be ten times more reliable than 1.5-nm SiO/sub 2/. 相似文献
5.
6.
Yamanaka N Aoyama T Ikeda N Higashihara M Kamata K 《Hemodialysis international. International Symposium on Home Hemodialysis》2005,9(3):303-308
Entropy (ENT) is a newly developed measure of the complexity of heart rate variability (HRV). The aim of this study was to characterize the complexity of HRV in patients with end-stage renal disease (ESRD) and to find a possible clinical utility. Healthy subjects and patients with ESRD undergoing hemodialysis (HD) were recruited. The HD population consisted of patients with and without diabetes mellitus (DM). An electrocardiogram was recorded before HD, and blood pressure was measured during HD. The coefficients of variation of R-R intervals, high- and low-frequency components, and ratio of the low- to high-frequency components were measured as variables of HRV. The ENT was used to describe the complexity of HRV. Forty-six healthy subjects and 27 HD patients participated in this study. The ENT negatively correlated with the duration of DM (p = 0.001), systolic blood pressure (p = 0.003), and mean blood pressure (p = 0.004) before a HD session. ENT in HD patients was lower than that in healthy subjects (p < 0.01). ENT in HD patients with DM was lower than that in HD patients without DM (p < 0.01). The change in systolic blood pressure (DeltaSBP) during a HD session showed high correlations to ENT and ultrafiltration rate (UFR) of the dialyzer. The following equation was obtained: DeltaSBP = 2.25 x ENT - 2.28 x UFR - 21.27 (R2 = 0.805; p < 0.0001). ENT decreased with uremic and diabetic status. ENT also represents a possible prediction of hypotension during a HD session. 相似文献
7.
Manganese tetraarylthiosubstituted phthalocyanines (complexes 1-5) have been deposited on Au electrode surfaces through the self assembled monolayer (SAM) technique. SAM characteristics reported in this work are: ion barrier factor (∼1); interfacial capacitance (303-539 μF cm−2) and surface coverage (1.06 × 10−10-2.80 × 10−10 mol cm−2). Atomic force microscopy was employed in characterizing a SAM. SAMs of complexes 1-5 were employed to detect l-cysteine (with limit of detection ranging from 2.83 × 10−7 to 3.14 × 10−7 M at potentials of 0.68-0.75 V vs. Ag|AgCl) and nitrite (limit of detection ranging from 1.78 × 10−7 to 3.02 × 10−7 M at potentials of 0.69-0.76 V vs. Ag|AgCl). 相似文献
8.
9.
Tono K Kudo T Yabashi M Tachibana T Feng Y Fritz D Hastings J Ishikawa T 《The Review of scientific instruments》2011,82(2):023108
We have developed an x-ray beam-position monitor for detecting the radiation properties of an x-ray free electron laser (FEL). It is composed of four PIN photodiodes that detect backscattered x-rays from a semitransparent diamond film placed in the beam path. The signal intensities from the photodiodes are used to compute the beam intensity and position. A proof-of-principle experiment at a synchrotron light source revealed that the error in the beam position is reduced to below 7 μm by using a nanocrystal diamond film prepared by plasma-enhanced chemical vapor deposition. Owing to high dose tolerance and transparency of the diamond film, the monitor is suitable for routine diagnostics of extremely intense x-ray pulses from the FEL. 相似文献
10.
Katsuhiko Moriyama Toru Sugiue Yuki Saito Shoichi Katsuta Hideo Togo 《Advanced Synthesis \u0026amp; Catalysis》2015,357(9):2143-2149
Benzoic acid catalysts bearing two amide groups that increase the Brønsted acidity of the carboxylic acid moiety by internal hydrogen‐bonding interactions were designed as a novel class of carboxylic acid catalysts for the Friedel–Crafts reaction of indoles with β‐nitrostyrenes and 3,3‐disubstituted 3H‐indoles to obtain the corresponding Friedel–Crafts adducts in high yields. The internal hydrogen‐bonding benzoic acid catalysts have a relatively high Brønsted acidity compared with benzoic acid based on the pKa measurements in DMSO by UV spectrophotometric titration.