首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   64篇
  免费   3篇
化学工业   19篇
金属工艺   1篇
建筑科学   2篇
轻工业   6篇
水利工程   1篇
无线电   3篇
一般工业技术   33篇
原子能技术   1篇
自动化技术   1篇
  2022年   3篇
  2021年   2篇
  2020年   1篇
  2018年   1篇
  2016年   2篇
  2015年   2篇
  2014年   6篇
  2013年   5篇
  2012年   12篇
  2011年   5篇
  2010年   2篇
  2009年   6篇
  2008年   4篇
  2007年   5篇
  2006年   1篇
  2004年   2篇
  2003年   2篇
  2002年   2篇
  2001年   1篇
  1996年   1篇
  1992年   1篇
  1983年   1篇
排序方式: 共有67条查询结果,搜索用时 15 毫秒
1.
The paper describes an analysis of reliability of railway traffic personnel. The human tasks critical to system safety are identified. Human error probability is chosen as a measure of human reliability in performing these tasks. The probabilities of some critical errors are estimated using the field data collected in the Slovenian railway traffic system. As stress conditions strongly affect the human performance, a simple model of the dependence of human error probability on stress levels is proposed.  相似文献   
2.
In the field of humidity quantities, the first CIPM key comparison, CCT-K6 is at its end. The corresponding European regional key comparison, EUROMET.T-K6, was completed in early 2008, about 4?years after the starting initial measurements in the project. In total, 24 NMIs from different countries took part in the comparison. This number includes 22 EURAMET countries, and Russia and South Africa. The comparison covered the dew-point temperature range from ?50?°C to +20?°C. It was carried out in three parallel loops, each with two chilled mirror hygrometers as transfer standards in each loop. The comparison scheme was designed to ensure high quality results with evenly spread workload for the participants. It is shown that the standard uncertainty due to the long-term instability was smaller than 0.008?°C in all loops. The standard uncertainties due to links between the loops were found to be smaller than 0.025?°C at ?50?°C and 0.010?°C elsewhere. Conclusions on the equivalence of the dew-point temperature standards are drawn on the basis of calculated bilateral degrees of equivalence and deviations from the EURAMET comparison reference values (ERV). Taking into account 16 different primary dew-point realizations and 8 secondary realizations, the results demonstrate the equivalence of a large number of laboratories at an uncertainty level that is better than achieved in other multilateral comparisons so far in the humidity field.  相似文献   
3.
Context: Comparative evaluation of liquid and solid self-microemulsifying drug delivery systems (SMEDDS) as promising approaches for solubility enhancement.

Objective: The aim of this work was to develop, characterize, and evaluate a solid SMEDDS prepared via spray-drying of a liquid SMEDDS based on Gelucire® 44/14 to improve the solubility and dissolution rate of naproxen.

Material and methods: Various oils and co-surfactants in combination with Gelucire® 44/14 were evaluated during excipient selection study, solubility testing, and construction of (pseudo)ternary diagrams. The selected system was further evaluated for naproxen solubility, self-microemulsification ability, and in vitro dissolution of naproxen. In addition, its transformation into a solid SMEDDS by spray-drying using maltodextrin as a solid carrier was performed. Scanning electron microscopy (SEM), differential scanning calorimetry (DSC), and X-ray diffraction (XRD) were used to evaluate the physical characteristics of the solid SMEDDS obtained.

Results: The selected formulation of SMEDDS was comprised of Miglyol 812®, Peceol?, Gelucire® 44/14, and Solutol® HS 15. The liquid and solid SMEDDS formed a microemulsion after dilution with comparable average droplet size and exhibited uniform droplet size distribution. In the solid SMEDDS, liquid SMEDDS was adsorbed onto the surface of maltodextrin and formed smooth granular particles with the encapsulated drug predominantly in a dissolved state and partially in an amorphous state. Overall, incorporation of naproxen in SMEDDS, either liquid or solid, resulted in improved solubility and dissolution rate compared to pure naproxen.

Conclusion: This study indicates that a liquid and solid SMEDDS is a strategy for solubility enhancement in the future development of orally delivered dosage forms.  相似文献   
4.
Characterization of steel mill electric-arc furnace dust   总被引:4,自引:0,他引:4  
In order to make a complete characterization of electric-arc furnace (EAF) dust, as hazardous industrial waste, and to solve its permanent disposal and/or recovery, bearing in mind both the volumes formed in the Croatian steel industry and experiences of developed industrial countries, a study of its properties was undertaken. For this purpose, samples of EAF dust, taken from the regular production process in the Zeljezara Sisak Steel Mill between December 2000 and December 2001, were subjected to a series of tests. The chemical composition of EAF dust samples was investigated by means of a several different analytical methods. The results from the chemical analysis show that the approximate order of abundance of major elements in EAF dusts is as follows: Fe, Zn, Mn, Ca, Mg, Si, Pb, S, Cr, Cu, Al, C, Ni, Cd, As and Hg. Granular-metric composition of single samples was determined by applying sieve separation. Scanning electron micro-structural examination of EAF dust microstructure was performed and results indicated that all twelve EAF dusts were composed of solid spherical agglomerates with Fe, Zn, Pb, O, Si and Ca as the principal element. The investigation of grain morphology and the mineralogical composition of EAF dust were taken by combination of high resolution Auger electron spectroscopy (HR AES), X-ray photoelectron spectroscopy (XPS) and X-ray powder diffraction analysis. The analysis of XPS-spectra determined the presence of zinc in the form of ZnO phase and the presence of lead in the form of PbO phase, i.e. PbSO3/PbSO4 forms. The results of the X-ray diffraction phase analysis show that the basis of the examined EAF dust samples is made of a mixture of metal oxides, silicates and sulphates. The metal concentration, anions, pH value and conductivity in water eluates was determined in order to define the influence of EAF dust on the environment.  相似文献   
5.
Auger electron spectroscopy (AES) depth profiling was used to study the oxidation phenomena of AISI316L stainless steel during treatment with oxygen plasma. Samples were exposed to low-pressure RF plasma with a high dissociation degree, so that the flux of oxygen atoms onto the sample surface exceeded 1024 m−2 s−1. A set of samples was oxidized 4 min at different temperatures up to 1300 K during plasma treatment. AES measurements showed that the oxide film thickness increased with the increasing temperature. The thickness of the oxide film on the samples oxidized in plasma at 300 K was nearly the same as for the untreated sample. The thickness of the oxide film of the samples which were oxidized at 1000 K was about 170 nm and it consisted of iron oxide. The thickest oxide film of about 350 nm was found on the samples heated in oxygen plasma to 1300 K. Depth profiling showed the uppermost layer of manganese oxide, followed by a mixture of chromium oxide and iron oxide. The scanning electron microscope analyses showed a dramatic increase of the surface roughness.  相似文献   
6.
7.
Attachment of polysaccharide fucoidan to the polyethylene terephthalate (PET) polymer surface was studied by X-ray photoelectron spectroscopy (XPS). Fucoidan has antithrombogenic and anticoagulant properties and is therefore a promising coating for vascular graft implants for improving their hemocompatibility. Samples of PET polymer were first modified by nitrogen plasma treatment in order to change the surface wettability and to introduce amino groups to the surface, which act as a linker for further binding of fucoidan. Plasma treated samples were then incubated for 30 min in fucoidan solution. The presence of fucoidan layer on the polymer surface was demonstrated by appearance of S2p signal in the XPS spectra of the coated PET samples. The procedure for immobilization of fucoidan on PET surface was optimized by varying pH value of fucoidan solution from 5 to 7.4. The best results were obtained when using lower pH value pH = 5. At these conditions the thickness of the fucoidan coating was estimated to about 7 nm.  相似文献   
8.
A European research project METefnet addresses a fundamental obstacle to improving energy-intensive drying process control: due to ambiguous reference analysis methods and insufficient methods for estimating uncertainty in moisture measurements, the achievable accuracy in the past was limited and measurement uncertainties were largely unknown. This paper reports the developments in METefnet that provide a sound basis for the SI traceability: four new primary standards for realizing the water mass fraction were set up, analyzed and compared to each other. The operation of these standards is based on combining sample weighing with different water vapor detection techniques: cold trap, chilled mirror, electrolytic and coulometric Karl Fischer titration. The results show that an equivalence of 0.2 % has been achieved between the water mass fraction realizations and that the developed methods are applicable to a wide range of materials.  相似文献   
9.
Thin film deposits of carbon and tungsten on stainless steel substrate were prepared by RF sputtering of a tungsten target in acetylene atmosphere. At the target bias of − 1700 V and the target current of 30 mA cm− 2, a rather uniform film containing 50 at.% of C and 50 at.% of W was deposited. The thickness of the deposited film was about 1 μm. Samples were exposed to highly dissociated hydrogen plasma created by a microwave discharge at the power of 1000 W. Some samples were heated additionally by concentrated solar radiation. After plasma treatment, the samples were characterized by X-Ray Diffraction and Auger Electron Spectroscopy. The results showed that aggressive hydrogen plasma allows for the removal of carbon from the deposits at moderated temperatures. Prolonged treatment showed formation of highly crystalline pure tungsten, and finally the tungsten film interacted with the substrate forming a thin film rich of Fe7W6 compound. The range of temperature and/or treatment time for the removal of carbon from the W-C film was found very narrow.  相似文献   
10.
Human exposure to the fluoride (F) from commercial teas was assessed. The efficacy of the F leaching was determined from the total F (Ft) contents in the teas (53–435 mg/kg) and the F concentrations in tea infusions (0.31–3.55 mg/l of free F available to human organism). Both were determined with a fluoride ion selective electrode. The efficacies of F leaching from the green, oolong and black teas were 55–90% with continuous, and 74–100% by repeated infusions, and were not affected by the type or the manufactured form. Lower efficacies were observed from Pu’erh teas, 21–38% with continuous, and 37–59% by repeated infusions. The daily intake of F with daily consumption of five cups of tea can represent 9–101% of the adequate intake (AI) for an adult person with 70 kg, and with tea and diet 25–173% of the AI in non-fluoridated and 35–210% of AI in fluoridated areas. The upper limits of these intakes can be already associated with a risk of developing F-related adverse effects.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号