排序方式: 共有5条查询结果,搜索用时 0 毫秒
1
1.
2.
Rameika R. Cox B. Jenkins C. M. Judd D. J. Hale G. Mazur P. O. Murphy C. T. Turkot F. Wagoner D. E. Conetti S. Haire M. Lebrun P. Leroy C. Ryan T. Turnbull L. Gearhart R. A. Shen C. 《IEEE transactions on nuclear science》1984,31(1):60-63
A hodoscope has been constructed from 100 ?m diameter wires and brass tubes (1.2 × 0.7 cm2 cross section) filled with a mixture of argon, ethane and ethyl alchohol. It has been tested in the saturated avalanche mode in an SCG1-C electromagnetic shower detector to determine its properties for the measurement of the position and size of electromagnetic showers. Two of these tube hodoscopes were positioned 3.5 radiation lengths deep in the detector and the profiles of 1-25 GeV electromagnetic showers were measured. Simultaneous measurements were performed using a plane of twenty, 0.5 cm wide scintillation counters positioned immediately behind the gas tube hodoscope. In addition the transition between saturated avalanche and limited streamer modes has been measured for the tube hodoscopes. 相似文献
3.
4.
Wagoner D. E. Cox B. Judd D. J. Hale G. Mazur P. O. Murphy C. T. Rameika R. Turkot F. Conetti S. Haire M. Lebrun P. Leroy C. Ryan T. Turnbull L. Gearhart R. A. Tzamarias S. 《IEEE transactions on nuclear science》1984,31(1):53-56
We report the measurement of the energy resolution of a 4×4 array of SCG1-C scintillation glass counters (Ohara Optical Glass Manufacturing Co., Ltd.) exposed to positrons in the energy range of 1 to 25 GeV. Each element of the array was 20.5 radiation lengths long. The resolution of the array was measured both with and without a 3.5 radiation length SCG1-C scintillation glass active converter and 0.2 radiation length hodoscopes used to measure shower position. We obtained an energy resolution ?/E = (1.63 + 1.46/?E)% without the active converter and ?/E = (0.64 + 3.94/?E)% with the active converter. Performing a partial correction for the average energy loss in the 0.2 radiation length hodoscopes resulted in an energy resolution of ?/E = (0.50 + 3.43/?/E)% for the active converter measurement. We also report on the measurement of the absolute number of photons produced by 1 GeV showers, the optical attenuation length for the light produced by showers, the fraction of the total light output that is due to Cerenkov light relative to scintillation light for showers, and the radiation darkening sensitivity of the scintillation glass. 相似文献
5.
R. Rameika B. Cox C.M. Jenkins D.J. Judd G. Hale P.O. Mazur C.T. Murphy F. Turkot D.E. Wagoner S. Conetti M. Haire P. Lebrun C. Leroy T. Ryan L. Turnbull R.A. Gearhart C. Shen 《Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment》1985,236(1):42-46
A hodoscope has been constructed from 100 μm diameter wires and brass tubes (1.2 × 0.7 cm2 cross section) filled with a mixture of argon, ethane and ethyl alcohol. It has been tested in the saturated avalanche mode in an SCG1-C electromagnetic shower detector to determine its properties for the measurement of the position and size of electromagnetic showers. Two of these tube hodoscopes were positioned 3.5 radiation lengths deep in the detector and the profiles of 1–25 GeV electromagnetic showers were measured. Simultaneous measurements were performed using a plane of twenty, 0.5 cm wide scintillation counters positioned immediately behind the gas tube hodoscope. In addition the transition between saturated avalanche and limited streamer modes was observed for the tube hodoscopes. 相似文献
1