This study investigates the relationship between the critical surface tension of wetting of celestite and agglomeration recovery as well as the zeta potential in dependence of pH and amount of collector (Na‐Oleate). For this purpose, effects of pH and collector amount on the agglomeration recovery are investigated and zeta potential measurements and Fourier Transform Infrared Spectrophotometer (FTIR) analyses are carried out to determine the adsorption type of Na‐Oleate on celestite surface. The sessile drop technique is used for the measurement of contact angle and determination of the critical surface tension of wetting (YC) of celestite. The maximum agglomeration recovery is obtained at pH 7. The critical surface tension of wetting of celestite is very close to the surface tension of kerosene, which is 25.95 mN/m. Furthermore, at the optimum Na‐Oleate amount of 10 kg/ton, the critical surface tension of wetting of celestite is approximately equal to the surface tension of kerosene. 相似文献
1. 1. System design optimization and validation for single-speed heat pump by S.K. Fischer and C.K. Rice, Oak Ridge National Laboratories.
2. 2. Analysis of on/off cycling for an air-to-air heat pump operating in the heating mode by W.A. Miller, Oak Ridge National Laboratories.
3. 3. Field measured cycling, frosting and defrosting losses for a high efficiency air source heat pump by V.D. Baxter and J.C. Moyers, Oak Ridge National Laboratories.
4. 4. Design and available energy analysis of a heating-only residential heat pump for the Western Pacific Northwest by D.E. Elger, C.M. Reistad and S. Lang, Oregon State University.
5. 5. A study of heat pump service life by Nance C. Lovvorn, Alabama Power Company and Carl C. Hiller, Electric Power Research.
Résumé
1. 1. Optimisation de la conception des systèmes et application à la pompe à chaleur à une seule vitesse;
2. 2. analyse du cycle par tout ou rien d'une pompe à chaleur air-air fonctionnant en mode de chauffage;
3. 3. pertes en fonctionnement cyclique, par givrage et dégivrage mesurées sur place pour une pompe à chaleur de grand rendement dont la source est l'air;
4. 4. conception et analyse de l'énergie disponible d'une pompe à chaleur uniquement pour le chauffage de locaux résidentiels sur la côte du Pacifique nord-ouest occidental;
5. 5. étude de la durée de vie d'une pompe à chaleur.
Les noms et les addresses des auteurs se trouvent dans le sommaire anglais. 相似文献
A type of CO2 sensor based on oxygen concentration cell was designed as following: Cell I: Pt | Au, O2,CO2|Na2CO3(Au)|NKBA(Au)|YSZ|O2, CO2|Pt or Cell Ⅱ: Pt|Au, O2, CO2|K2CO3(Au)|NKBA(Au)|YSZ|O2, CO2|Pt.(Na,K-β/β″-Al2O3 is named by NKBA). The sensor signal is consistent with the Nernstian slope within the region ofphase equilibrium for Na, K-β/β"-Al2O3 material. The relationship between CO2 sensor voltage response and phaseequilibrium of solid electrolyte Na, K-β/β-Al2O3 is discussed in this paper. 相似文献
The search for high-efficiency, gas-fired cooling cycles has led to the development of dual-loop absorption machines with cooling coefficients of performance (COPs) in the 1.2 to 1.7 range. This increased performance may call for high generator temperatures, new working fluids or new materials of construction. In most cases, two different sets of working fluids are required. The conceptual design presented here is aimed at obtaining high efficiencies with relatively low temperatures, employing only one set of fluids. The concept consists of two loops coupled in a configuration aimed at minimizing the loss of thermodynamic availability incurred when transferring refrigerant between the loops. The working fluid pair is a solution of lithium bromide-water. The calculated COPs are of the order of 1.8. The cycle relies on an elaborate evaporator-absorber combination. The paper presents the conceptual design, the critical assumptions, and the performance calculations for the concept. 相似文献