排序方式: 共有44条查询结果,搜索用时 15 毫秒
1.
2.
Baki Hazer Songun I. Demirel Mehlika Borcakli Mehmet S. Eroglu Miko Cakmak Burak Erman 《Polymer Bulletin》2001,46(5):389-394
Summary
Poly(-3-hydroxy alkanoate) containing unsaturated side chains, PHA-soybean, were produced by feeding Pseudomonas oleovorans with soybean oily acids obtained from soybean oil. Unsaturation of PHA-soybean were found to be 10 mol-% of unsaturated side
chains.
Main saturated part of the biopolymer was Poly(3-hydroxy octanoate) with minor hexanoate and decanoate units. PHA films were
crosslinked via free radical mechanism by means of thermally or under UV irradiation in the presence of benzoyl peroxide,
benzophenon, and /or ethylene glycol dimethacrylate (EGDM). Crosslinking yield of the PHA films were found to be from 81 to
93 wt.-% from the sol-gel analysis. Swelling properties of the crosslinked PHA films in chloroform and toluene were also studied.
Mc values of crosslinked PHAs were also calculated using Flory-Rehner equation. The crosslinked biopolyester obtained by thermally
at 60 °C with benzoyl peroxide indicated the highest crosslinking density. Glass transition temperatures (Tg) of crosslinked
biopolyester samples were changed from −33 to −45 °C while that of PHA-soybean was −60 °C.
Received: 16 June 2000/Revised version: 22 January 2001/Accepted: 20 May 2001 相似文献
3.
AKHLAGHI Mehdi AHI Leyla Pashaye JALILIAN Amir Reza GAROUSI Javad POUR-HERAVI Mohammad Reza Abdolrahim 《核技术(英文版)》2009,20(3):163-169
In order to prepare a specific melanocortin type 2 receptor (MC2R) ligand, b1-24-corticotrophin was pre-pared in one-step reaction with [18F] SFB and b-1-24-corticotrophin pharmaceutical solution (1 mg/mL, pH=6.5). [18F]SFB was prepared in a semi-automated module in two steps with an overall radiochemical yield of 47% to EOB (not-decay corrected) in 90 min. The 18F-labeled intermediates and 18F-labeled peptide was checked by RTLC and HPLC. The results show that the radiochemical purity is >95% and the yield to EOB (not-decay corrected) is 29% for final 18F-labeled peptide at optimized conditions. Preliminary in vivo studies in normal mice were performed to deter-mine biodistribution of the 18F-labeled peptide for 150 min. The results show that the major tracer uptake is consistent with the natural distribution of MC2R receptors in mammals. Testes/blood and testes/muscle ratios for 18F-labeled peptide at 150 min were 184 and 1.56, respectively, and adipocyte/blood and adipocyte/muscle ratios at 120 min were 221 and 142, respectively. The data support the specific receptor binding of the radiolabeled peptide as reported for MC2R receptor accumulation in adipocytes and testes and demonstrates the retention of biological activity of the pep-tide. This tracer can be used in detection of MC2R distribution in malignancies and sex organ diseases. 相似文献
4.
We describe a liquid helium glass-fibre reinforced plastic (G-FRP) Dewar which we designed, fabricated and tested for excitation spectrum measurements in high pulsed magnetic fields of up to 50 T. The sensitivity of high-resolution magnetic measurements carried out at low temperatures in such high fields is limited inevitably by magnetic and electric properties of the structural Dewar materials involved. Magnetic properties of various G-FRP Dewar-purpose materials are explored with a χ-meter furnished with a RF SQUID magnetometer. The Dewar materials and multilayer insulation effects contributing to the magnetic response signal are analyzed. It has also been discovered that field noise caused by the magnetization of the Dewar materials can be suppressed substantially by using special glass-epoxy technologies. The liquid helium evaporation rate is 3.8 l/day while the hold time is 27 h, the influencing factors are discussed. 相似文献
5.
The insulation vacuum (<10−4 Pa) of the large hadron collider magnet cryostats, thermally protecting the superconducting magnets which operate at 1.9 K in superfluid helium, is divided in to 214 m long segments separated by means of insulation vacuum barriers.The insulation vacuum barrier is a leak-tight stainless steel welded structure, composed of two concentric corrugated cylinders and one internal bellows linked together by a 6 mm thick central plate. As the vacuum barrier mechanically links the cryostat vacuum vessel operating at ambient temperature and the 1.9 K superconducting magnets, it is designed to have minimum heat conductivity. Conduction heat in-leak is intercepted at 65 K by a high-purity copper ring brazed onto the stainless steel central plate and thermally linked to a cryogenic line by a copper-aluminium soldering. The thermal performance has been experimentally validated by cryogenic testing.This paper presents the results obtained after industrialisation, manufacture and testing of prototypes and series units. Qualification of leak-tight welds in thin-sheet stainless steel (thickness 0.15-1.3 mm) has been carried out. Ultrasonic testing is performed on all brazing and soldering. Helium leak testing is performed, using dedicated tooling, to ensure a leak-tightness to a rate better than 10−9 Pa m3 s−1. 相似文献
6.
Gujie Qian A. Guerra Yuan Shuanglong Guorong Chen 《Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms》2007,262(2):276-280
Irradiation resistance of as-studied scintillating glass samples were tested under the 60Co γ-ray radiation at doses between 60 and 700 Gy. Photoluminescence properties of glasses with and without cerium ions were investigated to show the effect of cerium (III) on the luminescence of ZnO. Ultraviolet and visible optical transmittance spectra were compared before and after irradiation treatment. The so-called radiation-induced absorption coefficient (RIAC) was introduced to compare more effectively the radiation damage on glass samples. The much reduced transmittance change and decreased RIAC value in UV-Vis region indicate that the density of electron centers and hole centers caused by radiation decreased, which helps to confirm that the reduction and oxidation reaction of cerium ions took place in radiation process. From RIAC curves, it can be seen that TiO2 enhances the irradiation resistance of sample in UV region. However, high TiO2 content has negative effect on visible transmittance of glasses after the higher dose irradiation (700 Gy). 相似文献
7.
S.H. Byun K. Chin W.V. Prestwich F.E. McNeill D.R. Chettle 《Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms》2007,263(1):116-118
A digital signal processor (DSP) based multichannel analyzer (MCA) has been developed for simultaneous acquisition of coincidence and anticoincidence γ-ray spectra. The shaped pulse from the spectroscopy amplifier is digitized by a flash analog-to-digital converter and then processed by a DSP. The coincidence mode operation is implemented by an external gate signal from a coincidence module. Fundamental performance was tested using NaI(Tl) detectors and compared with that of a standard NIM module. The new MCA is currently used for in vivo neutron activation analysis. Further development is in preparation toward full digital processing, which is free from the remaining analog component, that is the spectroscopy amplifier. 相似文献
8.
Timothy A. White John E. Schweppe 《Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms》2008,266(9):2079-2089
Creation of synthetic cargo-container radiographs that possess attributes of their empirical counterparts requires accurate models of the imaging-system response. Synthetic radiographs serve as surrogate data in studies aimed at determining system effectiveness for detecting target objects when it is impractical to collect a large set of empirical radiographs. In the case where a detailed understanding of the detector system is available, an accurate detector model can be derived from first-principles. In the absence of this detail, it is necessary to derive empirical models of the imaging-system response from radiographs of well-characterized objects. Such a case is the topic of this work, where we demonstrate the development of an empirical model of a gamma-ray radiography system with the intent of creating a detector-response model that translates uncollided photon transport calculations into realistic synthetic radiographs. The detector-response model is calibrated to field measurements of well-characterized objects thus incorporating properties such as system sensitivity, spatial resolution, contrast and noise. 相似文献
9.
A gravity assisted Gold coated heat pipe (GCHP) with 5-mm diameter has been developed and tested to cool a liquid hydrogen target for external beam experiments at COSY. The need for a narrow target diameter leads us to study the effect of reducing the heat pipe diameter to 5 mm instead of 7 mm, to study the effect of coating the external surface of the heat pipe by a shiny gold layer (to decrease the radiation heat load), and to study the effect of using the heat pipe without using 20 layers of‘ super-insulation around it (aluminized Mylar foil) to keep the target diameter as small as possible. The developed gold coated heat pipe was tested with 20 layers of super-insulation (WI) and without super-insulation (WOI). The operating characteristics for both conditions were compared to show the advantages and disadvantages. 相似文献
10.
选择MC9S08GB60和MC13192构建了一种实现ZigBee的硬件系统框架,并在此基础上阐述了电源电路、MC13192与MC9S08GB60接口电路和MC13192射频模块的详细设计:文章的最后介绍了硬件测试过程. 相似文献