首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   1篇
建筑科学   5篇
  2018年   1篇
  2016年   1篇
  2013年   1篇
  2012年   1篇
  2009年   1篇
排序方式: 共有5条查询结果,搜索用时 31 毫秒
1
1.
The TRNSYS energy analysis tool has been capable of simulating whole-building coupled heat transfer and building airflow for about 10 years. The most recent implementation was based on two TRNSYS modules, Type 56 and Type 97. Type 97 is based on a subset of the airflow calculation capabilities of the CONTAM multizone airflow and contaminant transport program developed by the National Institute of Standards and Technology. This paper describes the development of new CONTAM capabilities in support of an updated combined, multizone building heat transfer, airflow and contaminant transport simulation approach using TRNSYS. It presents an illustrative case that highlights the new coupling capability and also presents the application of this coupled simulation approach to a practical design problem of the energy use related to airflow through entry doors in non-residential buildings.  相似文献   
2.
A series of tests was conducted to characterize the indoor carbon monoxide (CO) concentrations resulting from portable electric generators operating in the attached garage of a test house under various use and environmental conditions. An extensive model validation effort using the multizone airflow and indoor air quality (IAQ) model CONTAM was carried out using the data from seven tests with a generator operating in the attached garage to compare predicted CO concentrations with measured values. The agreement between the measurements and predictions of the O2 concentrations in the garage and the average CO concentration for the house zones was excellent for the data set as a whole. The agreement was somewhat worse for the garage CO concentrations. Overall, the house zone average and garage CO concentration predictions and measurements were within about 20% and 30%, respectively, when averaged over all cases.  相似文献   
3.
Residential energy efficiency and ventilation retrofits (eg, building weatherization, local exhaust ventilation, HVAC filtration) can influence indoor air quality (IAQ) and occupant health, but these measures’ impact varies by occupant activity. In this study, we used the multizone airflow and IAQ analysis program CONTAM to simulate the impacts of energy retrofits on indoor concentrations of PM2.5 and NO2 in a low‐income multifamily housing complex in Boston, Massachusetts (USA). We evaluated the differential impact of residential activities, such as low‐ and high‐emission cooking, cigarette smoking, and window opening, on IAQ across two seasons. We found that a comprehensive package of energy and ventilation retrofits was resilient to a range of occupant activities, while less holistic approaches without ventilation improvements led to increases in indoor PM2.5 or NO2 for some populations. In general, homes with simulated concentration increases included those with heavy cooking and no local exhaust ventilation, and smoking homes without HVAC filtration. Our analytical framework can be used to identify energy‐efficient home interventions with indoor retrofit resiliency (ie, those that provide IAQ benefits regardless of occupant activity), as well as less resilient retrofits that can be coupled with behavioral interventions (eg, smoking cessation) to provide cost‐effective, widespread benefits.  相似文献   
4.
Indoor air quality (IAQ) has a significant influence on occupants' comfort, health, productivity, and safety. Existing studies show that the primary causes of many IAQ problems are various airborne contaminants that either are generated indoors or penetrate into indoor environments with passive or active airflows. Accurate and prompt identification of contaminant sources can help determinate appropriate IAQ control solutions, such as, eliminating contaminant sources, isolating and cleaning contaminated spaces. This study develops a fast and effective inverse modeling method for identifying indoor contaminant source characteristics. The paper describes the principles of the probability-based adjoint inverse modeling method and formulates a multi-zone model based inverse prediction algorithm that can rapidly track contaminant source location with known source release time in a building with many compartments. The paper details the inverse modeling procedure with modification of an existing multi-zone airflow and contaminant transport simulation program. The application of the method has been demonstrated with two case studies: contaminant releases in a multi-compartment residential house and in a complex institutional building. The numerical experiments tested the source identification capability of the program for various contaminant sensing scenarios. The investigation verifies the effectiveness and accuracy of the developed method for indoor contaminant source tracking, which will be further explored to identify more complicated indoor contamination episodes.  相似文献   
5.
Residents of low-income multifamily housing can have elevated exposures to multiple environmental pollutants known to influence asthma. Simulation models can characterize the health implications of changing indoor concentrations, but quantifying the influence of interventions on concentrations is challenging given complex airflow and source characteristics. In this study, we simulated concentrations in a prototype multifamily building using CONTAM, a multizone airflow and contaminant transport program. Contaminants modeled included PM(2.5) and NO(2) , and parameters included stove use, presence and operability of exhaust fans, smoking, unit level, and building leakiness. We developed regression models to explain variability in CONTAM outputs for individual sources, in a manner that could be utilized in simulation modeling of health outcomes. To evaluate our models, we generated a database of 1000 simulated households with characteristics consistent with Boston public housing developments and residents and compared the predicted levels of NO(2) and PM(2.5) and their correlates with the literature. Our analyses demonstrated that CONTAM outputs could be readily explained by available parameters (R(2) between 0.89 and 0.98 across models), but that one-compartment box models would mischaracterize concentrations and source contributions. Our study quantifies the key drivers for indoor concentrations in multifamily housing and helps to identify opportunities for interventions. PRACTICAL IMPLICATIONS: Many low-income urban asthmatics live in multifamily housing that may be amenable to ventilation-related interventions such as weatherization or air sealing, wall and ceiling hole repairs, and exhaust fan installation or repair, but such interventions must be designed carefully given their cost and their offsetting effects on energy savings as well as indoor and outdoor pollutants. We developed models to take into account the complex behavior of airflow patterns in multifamily buildings, which can be used to identify and evaluate environmental and non-environmental interventions targeting indoor air pollutants which can trigger asthma exacerbations.  相似文献   