首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   29篇
  免费   0篇
建筑科学   28篇
能源动力   1篇
  2016年   2篇
  2013年   1篇
  2011年   3篇
  2009年   1篇
  2008年   4篇
  2007年   7篇
  2006年   2篇
  2005年   1篇
  2002年   1篇
  2001年   2篇
  2000年   1篇
  1995年   1篇
  1992年   1篇
  1991年   2篇
排序方式: 共有29条查询结果,搜索用时 15 毫秒
1.
During the winter of 1988/1989, the relationships between the prevalence of work-related health and indoor climate complaints and a number of building, management, workplace and personal characteristics have been investigated in a study in more than 60 office buildings located throughout the Netherlands. To collect the information, a questionnaire was prepared on health and indoor climate complaints and personal and workplace characteristics. A checklist was used to obtain information on building characteristics More than 7000 questionnaires were completed by the regular users of the buildings investigated. The results showed that the prevalence of symptoms was higher in air-conditioned buildings than in naturally or mechanically ventilated buildings. some other variables were also related with most work-related complaints after adjustment for selected management, personal, workplace and job characteristics. These included gender, work satisfaction in general, presence of allergies and/or respiratory symptoms, and personal control over temperature at the workplace. No differences were found in symptom prevalences between buildings with spray and steam humidification. The combination of air-conditioning and humidification did not lead to further increases in the prevalence of complaints as compared to buildings with only airconditioning or only humidification.  相似文献   
2.
No More Stopping     
The dissolution of the conventional breaking points in the construction and completion phases of a building's delivery has blurred ‘the distinction between the production of design intent and the transmission of information’. Here Richard Garber , Director of the School of Architecture at the New Jersey Institute of Technology (NJIT), advocates that architects should use this as an opportunity to widen their remit, gaining agency and with it responsibility and the financial rewards to practice. Here he draws from the examples of UNStudio, GLUCK+ and his own New-York based practice, GRO Architects.  相似文献   
3.
Occupant responses and indoor environment characteristics were recorded and compared in five mechanically and four naturally ventilated open-plan office buildings by using a simple approach that enabled us to survey many buildings simultaneously. All occupant responses were obtained during one afternoon. In a pre-experiment, temperature and the concentration of CO2 were monitored in 2–10 locations/office to evaluate the variation throughout the offices. A representative measurement point was subsequently selected and measurements of the same parameters were made during one week. All offices were monitored during the same week and occupant responses to the indoor environment were collected via the internet on the same day within that week. The temperature and the CO2 concentration varied more and were in some cases higher in the naturally ventilated buildings, but occupant responses in terms of symptoms and adverse perceptions differed only modestly between the two building types. Although rarely supported by statistical significance, the results indicated a somewhat higher degree of satisfaction with the indoor environment and a lower prevalence/intensity of symptoms among the occupants in the naturally ventilated buildings.  相似文献   
4.
This paper characterizes the relationship between occupant activities and indoor air particulate levels in a non-smoking office building. Occupant activities were recorded on video. Particulate concentrations were monitored by three optical particle counters (OPCs) in five size ranges at three heights. Particulate mass concentrations were measured gravimetrically and bioaerosol concentrations were determined by impaction methods. Occupant activities and number concentrations were determined with 1-min resolution over a 1-week period. Occupant activities such as walking past or visiting the monitoring site explained 24-55% of the variation of 1- to 25-micron diameter particle number concentrations. Statistical models associating particulate concentrations with occupant activities depended on the size fraction and included an autocorrelative term. Occupant activities are estimated to contribute up to 10 micrograms m-3 in particulate concentrations per person. Number concentrations of particles smaller than 1 micron had little correlation with indoor activities other than cigarette smoking and were highly correlated with outdoor levels. The method can be used to characterize emissions from activities if rapid measurements can be made and if activities can be coded from the video record.  相似文献   
5.
We studied the performance of a task ventilation system that permits occupants to control the flow rate and direction of air supplied to their work space through four floor-mounted supply grill. Air exited the room through a ceding-mounted return grill. To study air-flow patterns, we measured the age of air at multiple locations using a tracer gas stepup. To study the intra-room transport of tobacco smoke particles, cigarettes were smoked mechanically in one workstation and particle concentrations were measured at multiple locations. Our major findings were as follows: (1) deviations from uniform age of air, and uniform particle concentration, were generally less than 30 percent; (2)some supply air short-circuits to the return grill when directed toward the return with high velocity; (3) low supply velocities resulted in a floor-to-ceiling displacement flow; (4) directing the supply air toward the occupant, of partially toward the occupant, typically yielded an age of air at the occupant's breathing level that was 15 to 25 percent lower than the age at other breathing-level locations; (5) with low supply velocities und air directed toward the occupants, tobacco smoke particle concentrations in a ventilated non-smoking workstation were 50 percent of the chamber-average concentration.  相似文献   
6.
Environmental tobacco smoke (ETS) has been identified as one of the factors associated with the symptoms of the sick building syndrome (SBS). We investigated the role of ETS in an office building during the phased introduction of a smoking ban. Over a two-year period we measured symptoms using a validated questionnaire, environmental nicotine levels and salivary cotinine as a biological marker of nicotine absorption in a stratified systemic sample of 375 office employees (91% response rate). In addition, 26 persons from a non-smoking office were studied as a control group. This report describes the findings derived from a cross-sectional analysis of the initial baseline data. Amongst the validated nonsmokers, symptoms increased with increasing nicotine exposure from ETS (r= 0.165 p < 0. 01), supporting the role of ETS in the SBS. Smokers reported significantly fewer symptoms than non-smokers, as has been found before, but were exposed to higher levels of airborne nicotine as expected. We suggest that this factor, along with the misclassification of smoking status, may have obscured an association between ETS exposure and the SBS in previous studies. An analysis of the findings after implementation of the smoking ban should provide further information on how much of the SBS is attributable to ETS in this study population.  相似文献   
7.
A typical UK office is used as an exemplar for office energy use in the UK. The effect of replacing existing boilers and air-conditioning systems with air-source heat pumps (ASHPs) is investigated for a “current” version of the office, with typical equipment/lighting usage, fabric and internal gains, and also for a “2030” office, where fabric is improved, equipment/lighting made more efficient and, as a result, internal gains reduced. The ASHPs, as a potential carbon-saving technology, performs slightly differently for the two office scenarios. Furthermore, after removing the boiler, it is found to be important whether electric hot water or gas hot water point-of-use heaters are adopted with the ASHPs (assuming that the existing boiler would not be used if the ASHPs is satisfying all space heating requirements). This can be the difference between ASHPs reducing and increasing the carbon emissions of the office. Finally, the carbon intensity of the grid has a large effect on the success of ASHPs technology. This is quantified through a sensitivity analysis, indicating the external conditions for which ASHPs might reduce CO2 emissions for office buildings. The results suggest that an ASHPs has the potential to reduce CO2 emissions for certain conditions, but should not be seen as a guaranteed low-carbon technology for all scenarios. As well as assessing the ASHPs as a carbon-saving technology, potential economic benefits are also estimated based on running costs and predicted reduction in energy bills.  相似文献   
8.
There is a large consensus concerning the expected trend, if not the magnitude of change, of the UK climate in the coming decades [Climate Change 2007: Impacts, Adaptation and Vulnerability, Intergovernmental Panel on Climate Change, April 2007]. This study aims to quantify how such changes will have a direct effect on heating and cooling energy use in future office environments (i.e. by the year 2030). When considering future offices, it is also necessary to account for a change in the small power and lighting equipment being used, in this case by assuming an improved efficiency in both categories. This will also have a significant effect on the balance of heating and cooling an office. Furthermore, the subtle effect of a change in location within the UK can affect results further, with northern cities having substantially higher heating loads (and lower cooling loads) than southern locations. Such factors can influence approaches towards reducing future office energy demands and, in some cases, be the difference between a heating-dominated or cooling-dominated building. This study should also inform future choices for supplying energy to office buildings, in particular microgeneration options. It confirms the importance of dealing with demand-side changes before assessing the supply-side opportunities, with buildings having very different heating and cooling needs post-refurbishment. The study also highlights the importance, and possibilities, of adapting to future climates, and the benefits of promoting heating-dominated buildings instead of cooling-dominated.  相似文献   
9.
Lam KS  Chan FS  Fung WY  Lui BS  Lau LW 《Indoor air》2006,16(2):86-97
A study was carried out to investigate the feasibility of achieving ultra low respirable suspended particulates (RSP) in commercial offices without major modification of existing ventilation systems by enhancing the particulates removal efficiency of existing central ventilation systems. Four types of filters which include pre-filters, cartridge filters, bag filters and high efficiency particulates air (HEPA) filters were tested in a commercial building in Causeway Bay. The results show that an RSP objective of <20 microg/m3 could be met by removing RSP from both the return air and outdoor air supply simultaneously. This level of performance is classed as 'excellent' by the Hong Kong Government, Environmental Protection Department. Filters with efficiency that exceed 80% placed both in the return air and outdoor air were sufficient to meet the objective. It is not necessary to install HEPA filters to achieve the 'excellent' class. The outdoor air filter has great influence on the steady state indoor RSP concentration while the effective cleaning rate is governed by the return air filter. Higher efficiency filters increased the static drop but the volume flow of the air fan was not affected significantly. The additional cost incurred was <5% of the existing operation cost. PRACTICAL IMPLICATIONS: This paper reports a field study of RSP control for an indoor office environment. The results are directly applicable to building service engineering in the design of ventilation systems using air-handling units. Field observations indicated that indoor RSP in an office environment could be suppressed below 20 microg/m3 within 1 h by the simultaneous filtration of outdoor air and return air. Outdoor air filtration has a great influence on the steady state indoor concentration and return air filtration governs the cleaning rate. It is believed that the results of this study could be extended to the cleaning of other indoor pollutants such as volatile organic compounds.  相似文献   
10.
No longer a leading architectural trend, Rationalism has fallen out of fashion. At best ‘marginalised’, even its tenets appear questionable. Guest-editors Andrew Peckham, Charles Rattray and Torsten Schmiedeknecht describe what motivated them to uncover and reassess the Rationalist sensibility among current European practices. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏