首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   60篇
  免费   0篇
金属工艺   1篇
建筑科学   7篇
能源动力   2篇
一般工业技术   47篇
原子能技术   3篇
  2015年   7篇
  2014年   2篇
  2013年   1篇
  2011年   4篇
  2009年   3篇
  2008年   4篇
  2007年   7篇
  2006年   2篇
  2005年   5篇
  2004年   7篇
  2003年   3篇
  2002年   6篇
  2001年   1篇
  1999年   2篇
  1998年   1篇
  1987年   2篇
  1986年   3篇
排序方式: 共有60条查询结果,搜索用时 15 毫秒
1.
This paper discusses the feasibility of a vapor compression/absorption hybrid refrigeration cycle for energy saving and utilization of waste heat. The cycle employs propane as a natural refrigerant and a refrigeration oil as an absorbent. A prototype of the cycle is constructed, in which a compressor and an absorption unit are combined in series. The performance of the cycle is examined both theoretically and experimentally. Although the solubility of the propane with the oil is not enough as a working pair in the absorption unit, the theoretical calculation shows that the hybrid cycle has a potential to achieve a higher performance in comparison with a simple vapor compression cycle by using the waste heat. In the experiment, the prototype cycle is operated successfully and it is found that an improvement of an absorber is necessary to achieve the good performance close to the theoretical one. The application of an AHE (absorber heat exchanger) can reduce the heat input to a generator. Further examinations on some other combinations of refrigerant/refrigeration oil and additives are desirable.  相似文献   
2.
A study, comparing the effect of blowing agent selection on energy consumption and the life cycle climate performance (LCCP) of a typical European refrigerator is discussed. Energy consumption of prototype European-style refrigerators made with a foam formulation with HFC-245fa as the blowing agent was measured and compared with energy consumption of the same model as currently produced (using a foam with a pentane blend for the blowing agent). Results were used in a LCCP study, considering both direct and indirect climate impacts due to blowing agent emissions and energy consumption in manufacturing processes and over the life cycle of the refrigerator. An assumption is made that the refrigerator is built and used in the European market.  相似文献   
3.
Hybrid-power gas engine heat pump (HPGHP) combines hybrid power technology with gas engine heat pump, which can keep the gas engine working in the economical zone. In this paper, a steady-state model of the HPGHP in heating condition has been established, the optimal torque curve control strategy is proposed to distribute power between the gas engine and battery pack. The main operating parameters of the HPGHP system are simulated on Matlab/Simulink and validated by experimental data, such as operating temperature, coefficient of performance (COP), fuel-consumed rate, etc. Heating capacity and COP of the heating pump system are validated under different ambient temperatures and water flow rates. The simulation and experiment results shows acceptable agreement, the maximum difference is respectively 8.9%, 5.9%, 9.5% and 8.2% for engine torque, motor torque, reclaimed heat and fuel-consumed rate. Based on the simulation results, HPGHP has the lowest fuel-consumed rate of 283 g (kWh)−1 at engine speed of 3000 rpm; the PER of HPGHP system is about 15.9% and 11.4% higher than the GHP under the same load in Mode C and D.  相似文献   
4.
The option of using natural working fluids as a substitute of R-22 for solar-boosted heat pumps depends not only upon thermal performance and hazardous rating but also on potential impacts on the environment. This paper presents the comparative assessment of natural working fluids with R-22 in terms of their characteristics and thermophysical properties, and thermal performance. Some justification is given for using natural working fluids in a solar boosted heat pump water heater. The results show that R-744 is not suitable for solar-boosted heat pumps because of its low critical temperature and high operational pressures. On the other hand, R-717 seems to be a more appropriate substitute in terms of operational parameters and overall performance. However, major changes in the heat pumps are required. R-290 and R-1270 are identified as candidates for direct drop-in substitutes for R-22.  相似文献   
5.
Refrigeration at dairy farms in Brazil would contribute substantially to improving the rate and quality of milk production. Farmers would be able to milk twice a day or more, and keep the milk refrigerated until it was transported to the delivery station. The 1980 rural electricity consumption in Brazil's major milk-producing state was only 0.93% of the national total2. This low consumption can be attributed to the high costs associated with the electrification of the rural regions. In these areas, cooling cycles based on the absorption principle may be especially suitable. Solar energy, coupled with methane generated from cattle herd wastes, has been investigated as a source of auxiliary energy.  相似文献   
6.
7.
Tubular daylight guidance systems are linear devices that channel daylight into the core of a building. They consist of a light transport section with, at the outer end, some device for capturing natural light and, at the inner end, a means of distributing the light within the interior. This technology is examined in terms of performance, cost, design issues and governance (codes) for the different generic types of systems. Gaps in the knowledge on a range of issues, particularly operational human factors, are identified as key determinants delaying the wider implementation of this technology.  相似文献   
8.
Energy consumption in residential buildings has gained an increasing interest the latest years due to the rising demand for efficient energy use and higher comfort standards. In tight building constructions with controlled ventilation, heat recovery with exhaust-air heat pump connected to floor heating is regarded as energy efficient heating system that optimises the energy use in buildings while maintaining an acceptable level of thermal comfort. In this study, we use the computational tools TRNSYS and EES to model and analyse the performance of a residential house, its ventilation system and its floor heating system based on an exhaust air heat pump. The system analysis focuses particularly on the influence of internal and solar gains on the operation of the heating system and the thermal comfort of the house. Furthermore, the way that gains influences the performance of the floor heating system is examined. Overall, the results bring to light the impact of factors that are not easy to predict on the indoor climate and the thermal comfort.  相似文献   
9.
Electricity usage by a household dishwasher can be reduced by using a heat pump system to heat the dishwasher cabinet, dishware and washing water. The evaporator obtains the energy from an energy storage unit which consists of a container filled with water which freezes to ice. The majority of the heat transfer from the energy storage to the evaporator occurs when ice is created in the energy storage unit. A transient simulation model of a dishwasher with a heat pump system was developed and compared to an experimental setup with good agreement. A simulation study of the compressor cylinder volume and the compressor operating time was performed. The results showed a 24% reduction in total electricity use compared to a dishwasher cycle using a traditional electric element.  相似文献   
10.
The advanced energy storage technology proposed and patented by authors can be applied for cooling, heating, dehumidifying, combined cooling and heating, and so on. It is also called the variable mass energy transformation and storage (VMETS) technology in which the masses in one or two storage tanks change continuously during the energy charging and discharging processes. This paper presents an advanced energy storage system using aqueous lithium bromide (H2O–LiBr) as working fluid. As one of VMETS systems, this system is a closed system using two storage tanks. It is used to shift electrical load and store energy for cooling, heating or combined cooling and heating. It is environmental friendly because the water is used as refrigerant in the system. Its working principle and process of energy transformation and storage are totally different from those of the traditional thermal energy storage (TES) systems. The electric energy in off-peak time is mostly transformed into the chemical potential of the working fluid and stored in the system firstly. And then the potential is transformed into cold or heat energy by absorption refrigeration or heat pump mode when the consumers need the cold or heat energy. The key to the system is to regulate the chemical potential by controlling the absorbent (LiBr) mass fraction or concentration in the working fluid with respect to time. As a result, by using a solution storage tank and a water storage tank, the energy transformation and storage can be carried out at the desirable time to shift electric load efficiently. Since the concentration of the working solution in the VMETS cycle varies continuously, the working process of the VMETS system is dynamic. As the first part of our study, the working principle and flow of the VMETS system were introduced first, and then the system dynamic models were developed. To investigate the system characteristics and performances under full-storage and partial-storage strategies, the numerical simulation will be performed in the subsequent paper. The simulation results will be very helpful for guiding the actual system and device design.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号