排序方式: 共有9条查询结果,搜索用时 343 毫秒
1
1.
The aim of this paper is to present a stochastic model to characterize the failure distribution of multi-unit systems when the current units state is imperfectly monitored. The definition of the hazard rate process existing with perfect monitoring is extended to the realistic case where the units failure time are not always detected (non-detection events). The so defined observed hazard rate process gives a better representation of the system behavior than the classical failure rate calculated without any information on the units state and than the hazard rate process based on perfect monitoring information. The quality of this representation is, however, conditioned by the monotony property of the process. This problem is mainly discussed and illustrated on a practical example (two parallel units). The results obtained motivate the use of the observed hazard rate process to characterize the stochastic behavior of the multi-unit systems and to optimize for example preventive maintenance policies. 相似文献
2.
Anne Barros Christophe Berenguer Antoine Grall 《Reliability Engineering & System Safety》2006,91(2):131
In this paper a maintenance policy is optimised for a two-unit system with a parallel structure and stochastic dependences. Monitoring problems are taken into account in the optimisation scheme: the failure time of each unit can be not detected with a given probability. Conditions on the system parameters (unit failure rates) and on the non-detection probabilities must be verified to make the optimisation scheme valid. These conditions are clearly identified. Numerical experiments allow to show the relevance of taking into account monitoring problems in the maintenance model. 相似文献
3.
4.
This paper presents a novel graphical approach to adjust and evaluate frequency-based relays employed in anti-islanding protection schemes of distributed synchronous generators, in order to meet the anti-islanding and abnormal frequency variation requirements, simultaneously. The proposed method defines a region in the power mismatch space, inside which the relay non-detection zone should be located, if the above-mentioned requirements must be met. Such region is called power imbalance application region. Results show that this method can help protection engineers to adjust frequency-based relays to improve the anti-islanding capability and to minimize false operation occurrences, keeping the abnormal frequency variation utility requirements satisfied. Moreover, the proposed method can be employed to coordinate different types of frequency-based relays, aiming at improving overall performance of the distributed generator frequency protection scheme. 相似文献
5.
6.
7.
工业电视和无损探伤技术相结合,可检测材料表面和内部缺陷并直观显示,为质量判定提供依据。文中介绍了由X射线管、图象增强管、摄象机和记录装置等构成的工业X射线电视检测法的原理及其主要设备功能,以及在板材和管材焊件探伤中的应用。并介绍了由紫外灯、摄象管、监视器和信息处理器等构成的工业电视荧光磁粉探伤法的原理、特点和应用范围。 相似文献
8.
This paper proposes a novel, passive-based anti-islanding method for both inverter and synchronous machine-based distributed generation (DG) units. Unfortunately, when the active/reactive power mismatches are near to zero, majority of the passive anti-islanding methods cannot detect the islanding situation, correctly. This study introduces a new islanding detection method based on exponentially damped signal estimation method. The proposed method uses adaptive identifier method for estimating of the frequency deviation of the point of common coupling (PCC) link as a target signal that can detect the islanding condition with near-zero active power imbalance. Main advantage of the adaptive identifier method over other signal estimation methods is its small sampling window. In this paper, the adaptive identifier based islanding detection method introduces a new detection index entitled decision signal by estimating of oscillation frequency of the PCC frequency and can detect islanding conditions, properly. In islanding conditions, oscillations frequency of PCC frequency reach to zero, thus threshold setting for decision signal is not a tedious job. The non-islanding transient events, which can cause a significant deviation in the PCC frequency are considered in simulations. These events include different types of faults, load changes, capacitor bank switching, and motor starting. Further, for islanding events, the capability of the proposed islanding detection method is verified by near-to-zero active power mismatches. 相似文献
9.
Anne Barros Christophe Berenguer Antoine Grall 《Reliability Engineering & System Safety》2006,91(2):131-136
In this paper a maintenance policy is optimised for a two-unit system with a parallel structure and stochastic dependences. Monitoring problems are taken into account in the optimisation scheme: the failure time of each unit can be not detected with a given probability. Conditions on the system parameters (unit failure rates) and on the non-detection probabilities must be verified to make the optimisation scheme valid. These conditions are clearly identified. Numerical experiments allow to show the relevance of taking into account monitoring problems in the maintenance model. 相似文献