1.
A theoretical and experimental study has been carried out for a residential brine-to-water CO2 heat pump system for combined space heating and hot water heating. A 6.5 kW prototype heat pump unit was constructed and extensively tested in order to document the performance and to study component and system behaviour over a wide range of operating conditions. The CO2 heat pump was equipped with a unique counter-flow tripartite gas cooler for preheating of domestic hot water (DHW), low-temperature space heating and reheating of DHW.

The CO2 heat pump was tested in three different modes: space heating only, DHW heating only and simultaneous space heating and DHW heating. The heat pump unit gave off heat to a floor heating system at supply/return temperatures of 33/28, 35/30 or 40/35 °C, and the set-point temperature for the DHW was 60, 70 or 80 °C. Most tests were carried out at an evaporation temperature of −5 °C, and the average city water temperature was 6.5 °C. The experimental results proved that a brine-to-water CO2 heat pump system may achieve the same or higher seasonal performance factor (SPF) than the most energy efficient state-of-the-art brine-to-water heat pump systems as long as: (1) the heating demand for hot water production constitutes at least 25% of the total annual heating demand of the residence, (2) the return temperature in the space heating system is about 30 °C or lower, (3) the city water temperature is about 10 °C or lower and (4) the exergy losses in the DHW tank are small.  相似文献   

2.
Heat sources for heat pumps in buildings as well as in industry are discussed. Furthermore, some environmental aspects concerning choice of heat source are highlighted. Only systems for heat pumping are included, i.e. air-conditioning types which can also partly work as heat pumps are excluded. Recent heat pump installations in Sweden are mainly in small systems. Ambient air, exhaust air, soil and rock are the most common heat source types. Data on COP, investment costs, working fluids, present Swedish market etc. for these types of heat sources are given. Data on industrial heat pump installations in some countries and distribution of these according to heat pump type and industry sector as well as heat source temperatures are reported. Process integration aspects when choosing heat source size and temperature are also discussed as well as the relation between these parameters and the choice of heat pump type. Finally, the influence on the economy of the heat source temperature is presented. The cost-effectiveness of heat pumps for reducing CO2 emissions compared with other heating technologies is discussed. The main results are: (1) heat pumps can in many cases in the future contribute to a reduction of CO2; (2) there is a rather big difference, for larger systems a major difference, between the water-based and the ambient air-based heat pumps in terms of efficient reduction of greenhouse gas emissions.  相似文献   
3.
The main purpose of this study is to investigate the performance of a transcritical CO2 cycle with an internal heat exchanger for hot water heating. Performance test and simulation have been carried out for a transcritical CO2 cycle by varying secondary heat transfer fluid temperatures at evaporator and gas-cooler inlets as well as the discharge pressure. Variations of mass flow rate of refrigerant, compressor power, heating capacity, and co-efficient of performance (COP) with respect to the length of an internal heat exchanger are presented at various operating conditions. Good quantitative agreement between model predictions and experimental results has been found; most parameters have absolute average deviations of less than 4%. As the length of the internal heat exchanger increases, COP is enhanced but heating capacity tends to decrease due to the trade-offs between the effectiveness and pressure drop in the internal heat exchanger.  相似文献   
4.
Energy consumption in residential buildings has gained an increasing interest the latest years due to the rising demand for efficient energy use and higher comfort standards. In tight building constructions with controlled ventilation, heat recovery with exhaust-air heat pump connected to floor heating is regarded as energy efficient heating system that optimises the energy use in buildings while maintaining an acceptable level of thermal comfort. In this study, we use the computational tools TRNSYS and EES to model and analyse the performance of a residential house, its ventilation system and its floor heating system based on an exhaust air heat pump. The system analysis focuses particularly on the influence of internal and solar gains on the operation of the heating system and the thermal comfort of the house. Furthermore, the way that gains influences the performance of the floor heating system is examined. Overall, the results bring to light the impact of factors that are not easy to predict on the indoor climate and the thermal comfort.  相似文献   
5.
The cooling load in the winter season becomes significant in commercial buildings and hotels because of the wide usage of office equipment and improved wall insulation. In this study, a simultaneous heating and cooling multi-heat pump having four indoor units and an outdoor unit was designed and tested in five operation modes: cooling-only, heating-only, cooling-main, heating-main, and entire heat recovery. The performance of the system with R410a was optimized by adjusting the system's control parameters. In the cooling-main mode, the rate of the bypass flow to the heating-operated indoor unit was optimized by controlling the EEV opening of the outdoor unit. In the heating-main mode, the mass flow rate to the cooling-operated indoor unit was optimized by adjusting the EEV opening in the outdoor unit. In the entire heat recovery mode, the compressor speed was controlled to improve the system COP with appropriate heating and cooling capacities.  相似文献   
6.
Conventional working fluids (refrigerants) are being phased out worldwide to combat with the twin menace of ozone layer depletion and global warming and natural refrigerants are fast gaining favour lately. Single stage and multi stage refrigeration systems fail to widen the gap between heat source and heat sink temperatures required in many industrial applications requiring simultaneous heating and cooling and cascaded systems appear to be the best alternative. Modest research has been done in cascaded systems based on natural refrigerants thereby offering good potential for research. In this paper, a cascaded system for simultaneous heating and cooling (refrigeration and heat pump system) with a carbon dioxide based HT cycle and propane based LT cycle for simultaneous refrigeration and heating applications has been analyzed. To facilitate prediction of optimum performance parameters, performance trends with variation in the design parameters and operating variables have been presented in this article. Relevant expressions have been developed to serve as guidelines to the user for selecting appropriate design parameters like intermediate temperature so that the system yields optimum performance. Independently developed property codes have been employed for both carbon dioxide and propane for higher accuracy.  相似文献   
7.
Increased concern about the environmental impact of the refrigeration technology is leading toward design solutions aimed at improving the energy efficiency of the related applications, using eco-friendly refrigerants, i.e. ozone-friendly and with the least possible global warming potential (GWP). In this respect, carbon dioxide (ASHRAE R744) is seen today as one of the most promising refrigerants and is raising great interest in industrial and scientific fields. In the present work, the plant options are investigated, which are related to the design of air/water heat pumps for tap water using CO2. A comparison is made, in terms of energy efficiency, between a system working with CO2 and a similar one working with HFC R134a; such a comparison is carried out by means of a simulation model of a refrigerating machine/heat pump, characterized by a detailed representation of the heat exchangers, based on their subdivision into elementary volumes. Results show that carbon dioxide is an interesting substitute for synthetic fluids, if the design of the system is focused to take advantage of its properties.  相似文献   
8.
An integrated system for simultaneous production of triple-effect cooling and single stage heating is proposed in this paper to harness low grade solar energy. The proposed system combines the heliostat field with a central receiver and the ejector-absorption cycle with the shaft power driven transcritical CO2 cycle. A parametric study based on first and second laws of thermodynamics is carried out to ascertain the effect of varying the exit temperature of duratherm oil, turbine inlet pressure, and evaporators temperature on the energy and exergy output as well as on the energy and exergy efficiencies of the system. The results obtained indicate that major source of exergy destruction is the central receiver where 52.5% of the inlet solar heat exergy is lost followed by the heliostat where 25% of the inlet exergy is destroyed. The energy and exergy efficiencies of the integrated system vary from 32% to 39% and 2.5%–4.0%, respectively, with a rise in the hot oil outlet temperature from 160 °C–180 °C. It is further shown that increase in evaporator temperature of transcritical CO2 cycle from −20 °C to 0 °C increases the energy efficiency from 27.45% to 43.27% and exergy efficiency from 2.51% to 2.97%, respectively. The results clearly show how the variation in the values of hot oil outlet temperature, turbine inlet pressure, and the evaporator temperature of transcritical CO2 cycle strongly influences the attainable performance of the integrated system.  相似文献   
9.
Micro heat pumps, with dimensions in the order of centimetres, may in the future be utilised for the heating and/or cooling of buildings, vehicles, clothing, and other products or applications. A number of issues have yet to be solved, including the construction of a microscale compressor, and determination of micro heat exchanger heat transfer capacities. Test samples of micro heat exchangers and a corresponding test apparatus have been built. Some two-phase experiments with propane (R-290) as refrigerant have been conducted. Preliminary results for a micro condenser with 0.5 mm wide trapezoidal channels of 25 mm length showed that a heat flux of up to 135 kW/m2, based on the refrigerant-side area, was attainable. The corresponding overall heat transfer coefficient was 10 kW/(m2 K), with a refrigerant mass flux of 165 kg/(m2 s) and a refrigerant-side pressure drop of 180 kPa/m.  相似文献   
10.
A microwave assisted zeolite–water adsorption heat pump system was designed, manufactured and investigated experimentally. The influence of operation time of microwave oven on performance of the adsorption heat pump was studied. The performance criteria: coefficient of performance, specific cooling power and volumetric cooing power, were calculated for the designed and tested adsorption heat pump system. The regeneration of adsorbent bed was achieved very rapidly (35 min) by using microwave heating system. The poor thermal conductivity of adsorbent did not affect the periods of isosteric heating and isobaric desorption processes.  相似文献   