首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   83篇
  免费   0篇
建筑科学   2篇
一般工业技术   81篇
  2015年   1篇
  2009年   1篇
  2008年   9篇
  2007年   11篇
  2006年   10篇
  2005年   14篇
  2004年   3篇
  2003年   7篇
  2002年   13篇
  2001年   4篇
  2000年   2篇
  1999年   7篇
  1996年   1篇
排序方式: 共有83条查询结果,搜索用时 31 毫秒
1.
Heat and mass transfer in a falling film vertical in-tube absorber was studied experimentally with LiBr aqueous solution. The presented results include the effect of solution flow rate, solution subcooling and cooling water temperature on the absorption in a smooth copper tube 16.05 mm I.D. and 400 mm long. The experimental data in the previous report for a 1200-mm-long tube was also re-examined and compared. It was demonstrated by the observation of the flow in the tube that the break down of the liquid film into rivulets leads to deterioration of heat and mass transfer at lower film Reynolds number or in longer tubes. An attempt to evaluate physically acceptable heat and mass transfer coefficients that are defined with estimated temperature and concentration at the vapor–liquid interface was also presented.  相似文献   
2.
In this paper, a new solution cycle in the double absorption heat transformer is presented and the thermodynamic performance of this new cycle is simulated based on the thermodynamic properties of aqueous solution of lithium bromide. The results show that this new cycle is superior to the cycle being studied by some researchers. This new solution cycle has a wider range of operation in which the system maintains the high value of COP and has larger temperature lifts and operation stability. The relationship between the absorber and the absorbing evaporator is more independent and this makes the operation and control of the system more easier.  相似文献   
3.
This study focuses on an emulsion as a new thermal storage material for ice storage. Two types of emulsions were formed using an oil–water mixture with a small amount of additive. A silicone, light and lump oils were used. The water contents of the emulsions were 70, 80 and 90%. The additive was an amino group modified silicone oil. No depression of freezing point was observed for the emulsions because of their hydrophobic properties. In order to determine the structure of the emulsions, their electrical resistances were measured. Moreover, components of the liquids separating from the emulsions were analyzed. The results indicated that one emulsion was a W/O type emulsion, while the other was an O/W type. Finally, adaptability of the two emulsions to ice storage was discussed, it was concluded that a high performance ice slurry could be formed by the W/O type emulsion.  相似文献   
4.
A theoretical and experimental study has been carried out for a residential brine-to-water CO2 heat pump system for combined space heating and hot water heating. A 6.5 kW prototype heat pump unit was constructed and extensively tested in order to document the performance and to study component and system behaviour over a wide range of operating conditions. The CO2 heat pump was equipped with a unique counter-flow tripartite gas cooler for preheating of domestic hot water (DHW), low-temperature space heating and reheating of DHW.

The CO2 heat pump was tested in three different modes: space heating only, DHW heating only and simultaneous space heating and DHW heating. The heat pump unit gave off heat to a floor heating system at supply/return temperatures of 33/28, 35/30 or 40/35 °C, and the set-point temperature for the DHW was 60, 70 or 80 °C. Most tests were carried out at an evaporation temperature of −5 °C, and the average city water temperature was 6.5 °C. The experimental results proved that a brine-to-water CO2 heat pump system may achieve the same or higher seasonal performance factor (SPF) than the most energy efficient state-of-the-art brine-to-water heat pump systems as long as: (1) the heating demand for hot water production constitutes at least 25% of the total annual heating demand of the residence, (2) the return temperature in the space heating system is about 30 °C or lower, (3) the city water temperature is about 10 °C or lower and (4) the exergy losses in the DHW tank are small.  相似文献   

5.
The influence of 2-methyl-1-pentanol (2MP) on the cooling effect of pilot absorption chiller has been studied experimentally. In one experimental series the additive was injected into LiBr solution. The enhancement ratio up to 20% was observed at the optimum additive concentration. In the second experimental series the additive was injected into the refrigerant. The enhancement ratio became 32% at higher additive concentration. Different additive concentrations have been tested in both series. These experimental results clearly showed that the presence of the additive in the vapour phase, even in very small amounts, favours the enhancement more than the additive in the LiBr solution. Also, it has been noticed, that the additive travels around the absorption cycle during long-term operation.  相似文献   
6.
The main purpose of this study is to investigate the performance of a transcritical CO2 cycle with an internal heat exchanger for hot water heating. Performance test and simulation have been carried out for a transcritical CO2 cycle by varying secondary heat transfer fluid temperatures at evaporator and gas-cooler inlets as well as the discharge pressure. Variations of mass flow rate of refrigerant, compressor power, heating capacity, and co-efficient of performance (COP) with respect to the length of an internal heat exchanger are presented at various operating conditions. Good quantitative agreement between model predictions and experimental results has been found; most parameters have absolute average deviations of less than 4%. As the length of the internal heat exchanger increases, COP is enhanced but heating capacity tends to decrease due to the trade-offs between the effectiveness and pressure drop in the internal heat exchanger.  相似文献   
7.
The objectives of this paper are to obtain experimental data of surface tension and interfacial tension, and to develop a new model of Marangoni convection for the best selection of heat transfer additive in ammonia–water absorption systems. The basic mechanism of Marangoni convection in absorption systems was reviewed from the viewpoints of the surface tension and the interfacial tension gradients. Marangoni convection was successfully visualized using a shadow graphic method. The solubility limits of the additives in ammonia–water solution ranged from 500 to 3000 ppm depending on the heat transfer additives. These values are much higher than those in LiBr–H2O solution in which the solubility ranged from 70 to 400 ppm. The temperature gradient of the surface tension should not be a criterion for Marangoni convection inducement in NH3–H2O system. The concentration and temperature gradients of the interfacial tension should not be a criterion for Marangoni convection inducement in NH3–H2O system. The magnitude of the interfacial tension did not affect the occurrence of Marangoni convection either. It was found that addition of the heat transfer additive beyond the solubility limit assisted Marangoni convection occurrence, but should not be a criterion for Marangoni convection inducement. It was proposed that the radical-out model should be a criterion for Marangoni convection inducement within the solubility limit in NH3–H2O system.  相似文献   
8.
Thermal heat driven adsorption systems using natural refrigerants have been focused on the recent energy utilization trend. However, the drawbacks of these adsorption systems are their poor performance in terms of system cooling capacity and coefficient of performance (COP). The objective of this paper is to improve the performance of thermally powered adsorption cooling system by selecting new adsorbent–refrigerant pair. Adsorption capacity of adsorbent–refrigerant pair depends on the thermophysical properties (pore size, pore volume and pore diameter) of adsorbent and isothermal characteristics of the pair. In this paper, the thermophysical properties of two PAN types of activated carbon fibers (FX-400 and KF-1000) are determined from the nitrogen adsorption isotherms. The standard nitrogen gas adsorption/desorption measurements on various adsorbents at liquid nitrogen of temperature 77.3 K were performed. Surface area of each adsorbent was determined by the Brunauer, Emmett and Teller (BET) plot of nitrogen adsorption data. Pore size distribution was measured by the Horvath and Kawazoe (HK) method. As of the adsorption/desorption isotherms, FX-400 shows very small hysteresis when the value of P/Po exceeds 0.4, while KF-1000 has no hysteresis in the whole range of P/Po. The adsorption capacity of FX-400 is about 30% higher than that of KF-1000. The adsorption equilibrium data of activated carbon fiber (ACF)-methanol are presented and correlated with simple equations. The adsorption equilibrium data of ACF (KF-1000)-water also presented in order to facilitate comparison with those of ACFs-methanol pair. The results will contribute significantly in designing the adsorber/desorber heat exchanger for thermally driven adsorption cooling system.  相似文献   
9.
A W/O (water-in-oil) emulsion was made from a water–lamp oil mixture with higher water content and a small amount of an additive of amino group-modified silicone oil, and the emulsion could be changed into an ice slurry by cooling with stirring. By using a new continuous ice formation system proposed by one of the authors of this paper, the ice slurry could be formed continuously and stably in an ice formation vessel made of stainless steel. From the experimental results, the conditions were clarified for realizing continuous ice formation for 10 h without ice adhesion to the cooling wall. Moreover, in order to propagate supercooling dissolution of the emulsion effectively and to decrease viscosity in the ice slurry, voltages were applied to the emulsion and ice slurry formed, respectively, and it was clarified that the voltage impression was effective for both.  相似文献   
10.
This study focused ice slurry formation in an ice storage system using W/O emulsions with 70 and 80% water contents. Emulsions consisted of a silicone oil–water mixture with a small amount of amino-group-modified silicone oil additive. Ice slurry was formed by cooling the emulsion without ice adhesion to the cooling wall, as water in the emulsion did not directly contact the cooling wall. As the structure of W/O emulsion slowed the propagation rate of supercooling dissolution, voltage and ultrasonic wave were applied to the W/O emulsion to propagate dissolution more quickly and decrease maximum supercooling degree, respectively. Thus, the effects of voltage and ultrasonic wave applications on propagation rate were clarified.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号