首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   82篇
  免费   2篇
化学工业   4篇
建筑科学   4篇
能源动力   2篇
一般工业技术   74篇
  2016年   1篇
  2015年   12篇
  2014年   5篇
  2013年   5篇
  2009年   2篇
  2008年   2篇
  2007年   9篇
  2006年   6篇
  2005年   8篇
  2004年   5篇
  2003年   4篇
  2002年   5篇
  2001年   3篇
  2000年   2篇
  1999年   5篇
  1998年   3篇
  1996年   2篇
  1995年   1篇
  1992年   2篇
  1990年   1篇
  1986年   1篇
排序方式: 共有84条查询结果,搜索用时 531 毫秒
1.
Water-silicone oil emulsion with an additive, (C2H5O)3SiC3H6NH2, was examined as a heat storage material. A spiral tube used as a heat exchanger was immersed in a low temperature bath and the emulsion was circulated in the tube to make ice continuously. Ice was separated from the ice–liquid suspension in an outlet tank. The amount of formed ice, the temperatures of the inlet and the outlet of the heat exchanger, and the temperatures in the tube wall were measured and the overall heat transfer coefficient and the heat flux through the tube were calculated. Experiments were carried out, varying the flow rate, the temperature of cooling brine, and the thickness of tube wall. The condition under which slurry ice was formed continuously without adhesion of ice to the cooling wall was clarified. Though decrease in the thermal resistance of the tube increased the rate of ice formation or raised the brine temperature, it narrowed the range of the flow rate and of the brine temperature in which slurry ice was formed continuously.  相似文献   
2.
This study focuses on an emulsion as a new thermal storage material for ice storage. Two types of emulsions were formed using an oil–water mixture with a small amount of additive. A silicone, light and lump oils were used. The water contents of the emulsions were 70, 80 and 90%. The additive was an amino group modified silicone oil. No depression of freezing point was observed for the emulsions because of their hydrophobic properties. In order to determine the structure of the emulsions, their electrical resistances were measured. Moreover, components of the liquids separating from the emulsions were analyzed. The results indicated that one emulsion was a W/O type emulsion, while the other was an O/W type. Finally, adaptability of the two emulsions to ice storage was discussed, it was concluded that a high performance ice slurry could be formed by the W/O type emulsion.  相似文献   
3.
Thermal conductivity models of frozen soils were analyzed and compared with similar models developed for frozen foods. In total, eight thermal conductivity models and 54 model versions were tested against experimental data of 13 meat products in the temperature range from 0 to −40 °C. The model by deVries, with water+ice (wi) as the continuous phase, showed overall the best predictions. The use of wi leads generally to improved predictions in comparison to ice; water as the continuous phase is beneficial only to deVries model, mostly from −1 to −20 °C; fat is advantageous only to meats with high fat content. The results of this work suggest that the more sophisticated way of estimating the thermal conductivity for a disperse phase in the deVries model might be more appropriate than the use of basic multi-phase models (geometric mean, parallel, and series). Overall, relatively small differences in predictions were observed between the best model versions by deVries, Levy, Mascheroni, Maxwell or Gori as applied to frozen meats with low content of fat. These differences could also be generated by uncertainty in meat composition, temperature dependence of thermal conductivity of ice, measurement errors, and limitation of predictive models.  相似文献   
4.
In this paper, numerical and experimental investigations on a magnetic refrigeration device based upon the active magnetic regeneration (AMR) cycle operating near room temperature are presented. A numerical 1D model based on the transient energy equations is proposed for modelling the heat exchange between the magnetocaloric material and the carrier fluid in the regenerator bed. The validity of 1D AMR-numerical model is investigated through the recently developed magnetic cooling demonstrator by Clean Cooling Systems SA (CCS) at the University of Applied Sciences of western Switzerland (HES−SO). The obtained results including the temperature span, the coefficient of performance and the cooling power are presented and discussed. In general, good agreements have been noted between the experimental and numerical results.  相似文献   
5.
The viscosity and thermal conductivity of ZnO nanofluids with nanoparticle shapes of nearly rectangular and of sphere, were experimentally investigated under various volume concentrations of the nanoparticles, ranging from 0.05 to 5.0 vol.%. The viscosity of the nanofluids increased with increases in the volume concentration by up to 69%. In addition, the enhancement of the viscosity of the nearly rectangular shape nanoparticles was found to be greater by 7.7%, than that of the spherical nanoparticles. The thermal conductivity of the ZnO nanofluids increased by up to 12% and 18% at 5.0 vol.% for the spherical and the nearly rectangular shape nanoparticles, respectively, compared to that of the base fluid (water). The shape of the particles is found to have a significant effect on the viscosity and thermal conductivity enhancements.  相似文献   
6.
In a fin-tube heat exchanger the contact between fin collar and tube surface is obtained through mechanical expansion of tubes. Since the interfaces between the tubes and fins consist partially of metal-to-metal contact and partially of air, the features of heat transfer through the contact interfaces have not been fully investigated. The present study aims at the development of a new tool including an experiment and a numerical calculation for the estimation of the thermal contact conductance between the fin collar and tube surface, and pursues the evaluation of the factors affecting the thermal contact conductance in a fin-tube heat exchanger. Heat exchangers fabricated for the current study have been put to the test for heat balance in a vacuum chamber with water as an internal fluid. And a finite difference numerical scheme has been used for the data reduction of the experimental data to evaluate the thermal contact conductance. Fin-tube heat exchangers employed in the current research are of tube diameter of 7 mm with different tube expansion ratios, fin spacings, and fin types. The results of the present study imply that these parameters as well as hydrophilic fin coating have a significant effect on the thermal contact conductance. It has been discovered that the portion of the thermal contact resistance is not negligible compared with the total thermal resistance in a fin-tube heat exchanger, and this means that in order to reduce the thermal contact resistance thoughtful care should be taken in fabricating heat exchangers.  相似文献   
7.
The development of a computer program is presented in order to determine the heat conduction transfer in multilayer spherical products, hollow or solid, by means of the transfer function method. We can establish a methodology in order to determine heat flux and inner and/or outer temperatures for spherical solid multilayer products, and heat flux and temperatures in any intermediate point of the spherical multilayer products both hollow and solid. The program developed is designed for variable intervals and it allows for the inclusion of the superficial convection coefficient in the cases where it remains constant, or its exclusion from the mathematical model in the cases where it does not remain constant, as well as in the cases in which it does not exist (heating or cooling by superficial contact). The method was validated with oranges of average diameters between 7.73 and 7.89 cm and thickness of rind between 4.7 and 6.8 mm, and these showed good results.  相似文献   
8.
The heat transfer in heat exchangers is commonly calculated using the concept of Logarithmic Mean Temperature Difference (LMTD). As is well known this approach is only valid for counter-current and co-current heat exchanger configurations. For other configurations, corrections for the deviation from pure counter-current are introduced. From any standard text book in heat transfer it may be found that the LMTD approach may also be used if condensation and evaporation occurs in the heat exchanger. The purpose of the present paper is to investigate if the LMTD approach can be used in a compact brazed plate evaporator. It will be shown through integration of the governing equations that the LMTD approach indeed may be used for practical cases, even though deviations occur at small logarithmic mean temperature differences. The article presents suggestions on the correction factor (F) needed under some simplified assumptions in a compact brazed plate heat exchanger operating as an evaporator for heat pump and refrigeration applications.  相似文献   
9.
A novel experimental investigation of a solar cooling system in Madrid   总被引:5,自引:2,他引:3  
This paper reports novel experimental results derived through field testing of a part load solar energized cooling system for typical Spanish houses in Madrid during the summer period of 2003. Solar hot water was delivered by means of a 49.9 m2 array of flat-plate collectors to drive a single-effect (LiBr/H2O) absorption chiller of 35 kW nominal cooling capacity. Thermal energy was stored in a 2 m3 stratified hot water storage tank during hours of bright sunshine. Chilled water produced at the evaporator was supplied to a row of fan coil units and the heat of condensation and absorption was rejected by means of a forced draft cooling tower. Instantaneous, daily and period energy flows and energy balance in the installation is presented. System and absorption machine temperature profiles are given for a clear, hot and dry day's operation. Daily and period system efficiencies are given. Peak insolation of 969 W m−2 (at 12:30 solar time on 08/08/03) produced 5.13 kW of cooling at a solar to cooling conversion efficiency of 11%. Maximum cooling capacity was 7.5 kW. Cooling was provided for 8.67 h and the chiller required a threshold insolation of 711 W m−2 for start-up and 373 W m−2 for shut-down. A minimum hot water inlet temperature to the generator of 65 °C was required to commence cold generation, whereas at 81 °C, 6.4 kW of cooling (18.3% of nominal capacity) was produced. The absorption refrigeration machine operated within the generation and absorption temperature ranges of 57–67 and 32–36 °C, respectively. The measured maximum instantaneous, daily average and period average COP were 0.60 (at maximum capacity), 0.42 and 0.34, respectively. Energy flows in the system are represented on a novel area diagram. The results clearly demonstrate that the technology works best in dry and hot climatic conditions where large daily variations in relative humidity and dry bulb temperature prevail. This case study provides benchmark data for the assessment of other similar prototypes and for the validation of mathematical models.  相似文献   
10.
In the present paper, the refrigerant mixture R32/R290 (68%/32% by weight) is investigated as the drop-in replacement for R410A in household air conditioners. The GWP of it is only 22% of that of R410A. Theoretical and experimental investigations are conducted on the performance of the air conditioners working with both R32/R290 and R410A. Experimental results show that the refrigerant charge amount of R32/R290 is reduced by 30.0%–35.0%; the cooling and heating capacities are increased by 14.0%–23.7%. For further reducing charge amount and flammability, the micro-channel heat exchanger (condenser) is employed to replace the finned tube one. Compared with the R32/R290 system using finned tube heat exchanger, the R32/R290 charge amount and the power consumption are reduced by 34.1% and 0.4%, respectively; the cooling capacity and the COP are increased by 6.4% and 6.8%, respectively.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号