首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   29篇
  免费   0篇
一般工业技术   29篇
  2015年   3篇
  2014年   3篇
  2013年   1篇
  2009年   2篇
  2008年   6篇
  2007年   7篇
  2006年   3篇
  2005年   2篇
  2002年   1篇
  1990年   1篇
排序方式: 共有29条查询结果,搜索用时 0 毫秒
1.
This study focused ice slurry formation in an ice storage system using W/O emulsions with 70 and 80% water contents. Emulsions consisted of a silicone oil–water mixture with a small amount of amino-group-modified silicone oil additive. Ice slurry was formed by cooling the emulsion without ice adhesion to the cooling wall, as water in the emulsion did not directly contact the cooling wall. As the structure of W/O emulsion slowed the propagation rate of supercooling dissolution, voltage and ultrasonic wave were applied to the W/O emulsion to propagate dissolution more quickly and decrease maximum supercooling degree, respectively. Thus, the effects of voltage and ultrasonic wave applications on propagation rate were clarified.  相似文献   
2.
This paper describes and analyzes a novel design of multiple parallel-pass (MPP) microchannel tube condenser and its applications to automotive A/C systems. A flow distributor concept is introduced in MPP condenser in order to enable parallel flow arrangement in adjacent flow paths. Throughout analysis of two-phase flow and heat transfer processes in MPP condenser, a two-phase zone enlargement technique is developed to enhance condensation heat transfer and reduce pressure drop. Visual observation indicates a more uniform refrigerant quality entering the next cooling pass can be achieved in MPP condenser because superheated vapor through a pass-through hole on flow distributor directly injects into the separated liquid–vapor zone in a header tube. Performance test results show MPP condenser is able to improve heat transfer rate as high as 9.5% while its refrigerant mass flow increases 13.34% when comparing to a benchmark PF condenser.  相似文献   
3.
The objectives of this paper are to quantify the effect of Marangini convection on the absorption performance for the ammonia–water absorption process, and to visualize Marangoni convection that is induced by adding a heat transfer additive, n-octanol. A real-time single-wavelength holographic interferometer is used for the visualization using a He–Ne gas laser. The interface temperature is always the highest due to the absorption heat release near the interface. It was found that the thermal boundary layer (TBL) increased faster than the diffusion boundary layer (DBL), and the DBL thickness increased by adding the heat transfer additive. At 5 s after absorption started, the DBL thickness for 5 mass% NH3 without and with the heat transfer additive was 3.0 and 4.5 mm, respectively. Marangoni convection was observed near the interface only in the cases with heat transfer additive. The Marangoni convection was very strong just after the absorption started and it weakened as time elapsed. It was concluded that the absorption performance could be improved by increasing the absorption driving potential (xvbxvi) and by increasing the heat transfer additive concentration. The absorption heat transfer was enhanced as high as 3.0–4.6 times by adding the heat transfer additive that generated Marangoni convection.  相似文献   
4.
The development of the novel direct digital control (DDC)-based capacity controller for a direct expansion (DX) air conditioning (A/C) unit having variable-speed compressor and supply fan to simultaneously control indoor air temperature and relative humidity (RH) in a conditioned space served by the DX A/C unit has been reported in Part I of the two-part series. The results of preliminary controllability tests for the novel capacity controller presented in Part I, however, suggested that the controller developed was operational, with acceptable control accuracy but rooms for improvement with respect to control sensitivity. This paper, the second part of the two-part series, reports on the further development of the controller to improve its control sensitivity and the associated controllability test results. Both control accuracy and reasonable control sensitivity were achieved by incorporating a traditional Proportional–integral (PI) controller into the DDC-based capacity controller.  相似文献   
5.
New enhanced boiling tubes from Wolverine Tube Inc. (Turbo-B5) and Wieland-Werke AG (Gewa-B5) were investigated using R-134a and R-236fa as test fluids. The tests were done at saturation temperatures of 5 and 15 °C, mass flow rates from 4 to 35 kg m−2 s−1 and heat fluxes from 15 to 70 kW m−2. A new prediction method based on a theoretical analysis of thin film evaporation was used to propose a new correlating parameter. A large new database of local heat transfer coefficients was obtained and utilized to generate an improved prediction method for bundle boiling and the onset of dryout. Onset of dryout and the simultaneous reduction in heat transfer performance occurred at very high vapour quality on these enhanced tubes in convective bundle boiling. Furthermore, a direct comparison was made between the tubes operating in falling film and convective bundle boiling modes.  相似文献   
6.
A CO2 heat pump system using recovered heat from the stack coolant was provided for use in fuel cell vehicles, where the high temperature heat source like in internal combustion engine vehicles is not available. The refrigerant loop consists of an electric drive compressor, a cabin heater, an outdoor evaporator, an internal heat exchanger, an expansion valve and an accumulator. The performance characteristics of the heat pump system were investigated and analyzed by experiments. The results of heating experiments were discussed for the purpose of the development and efficiency improvement of a CO2 heat pump system, when recovering stack exhaust heat in fuel cell vehicles. A heater core using stack coolant was placed upstream of a cabin heater to preheat incoming air to the cabin heater. The performance of the heat pump system with heater core was compared with that of the conventional heating system with heater core and that of the heat pump system without heater core, and the heat pump system with heater core showed the best performance of the selected heating systems. Furthermore, the coolant to air heat pump system with heater core showed a significantly better performance than the air to air heat pump system with heater core.  相似文献   
7.
The paper is aimed to develop a high performance rotary solid desiccant cooling system using a novel compound desiccant wheel (DW). The unique feature of the desiccant wheel is that it can work well under a lower regeneration temperature and have a higher dehumidification capacity due to the contribution of the new compound desiccant materials. Experimental results indicate that the novel desiccant wheel under practical operation can remove more moisture from the process air by about 20–40% over the desiccant wheel employing regular silica gel. A mathematical model that is used to predict the system performance has been validated with the test results. By integrating the desiccant wheel with evaporative cooling, heat recovery and heating for regeneration sections, a solid desiccant cooling system can be formed. Simulation results show that because of the use of the new compound desiccant, the desiccant cooling system can work under much lower regeneration temperature and have a relative high COP, thus low grade thermal energy resources, such as solar energy, waste heat, etc., can be efficiently utilized to drive such a cooling cycle.  相似文献   
8.
The objectives of this paper are to visualize the bubble behavior during the NH3/H2O absorption process with chemical surfactant and nano-particles and to study the effect of nano-particles and surfactants on the absorption characteristics. Binary nanofluid which means binary mixture with nano-sized particles is tested to apply nanofluid to the absorption system. Cu, CuO and Al2O3 nano-particles are added into NH3/H2O solution to make the binary nanofluids, and 2-ethyl-1-hexanol, n-octanol and 2-octanol are used as the surfactants. The concentration of ammonia in the basefluid, that of nano-particles in the nanofluid, and that of surfactants in the nanofluid are considered as the key parameters. The results show that the addition of surfactants and nano-particles improves the absorption performance up to 5.32 times. It can be concluded that the addition of both surfactants and nano-particles enhances significantly the absorption performance during the ammonia bubble absorption process.  相似文献   
9.
This paper proposes a thermoelectric-assisted vapor compression cycle (TVCC) for applications in air-source heat pump systems which could enhance the heating capacity of the system. Performances of TVCC are calculated and then compared with that of basic vapor compression cycle (BVCC). The simulation results show that when coefficients of performance (COPs) of the two cycles are almost equal, the TVCC under maximum COP condition of the thermoelectric modules still performs better than BVCC by 13.0% in heating capacity through selecting the appropriate intermediate temperature. In addition, the TVCC can also achieve an improvement of 16.4%–21.7% in both the heating COP and capacity when compared with the BVCC with an assistant electric heater that is provided with the equivalent power input of thermoelectric heat exchanger. Thus, the TVCC could be beneficial to the applications in small heat pumps if there is always need for auxiliary electric heat.  相似文献   
10.
This paper presented a novel autocascade refrigeration cycle (NARC) with an ejector. In the NARC, the ejector is used to recover some available work to increase the compressor suction pressure. The NARC enables the compressor to operate at lower pressure ratio, which in turn improves the cycle performance. Theoretical computation model based on the constant pressure-mixing model for the ejector is used to perform a thermodynamic cycle analysis for the NARC with the refrigerant mixture of R23/R134a. The effects of some main parameters on cycle performance were investigated. The results show the NARC has an outstanding merit in decreasing the pressure ratio of compressor as well as increasing the COP. For NARC operated at the condenser outlet temperature of 40 °C, the evaporator inlet temperature of −40.3 °C, and the mass fraction of R23 is 0.15, the pressure ratio of the ejector reaches to 1.35, the pressure ratio of compressor is reduced by 25.8% and the COP is improved by 19.1% over the conventional autocascade refrigeration cycle.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号