摘    要:通过设计的程度和检验方法,利用数学模型和试验数据,详细论述了CL3601型交直流仪表对于开展0.2级及以下电压、电流、功率表检定的可行性。

关 键 词:CL3601型交直流仪表  测量  不确定度  评定
文章编号:1009-3230(2007)05-0034-02
修稿时间:2007-03-112007-04-07

Assessment of Uncertainty of Measuring Result of the CL3601 AC-DC Calibrating Apparatus
YUAN Li-jun,LI Hua-ming,HU Xing-wei. Assessment of Uncertainty of Measuring Result of the CL3601 AC-DC Calibrating Apparatus[J]. Applied Energy Technology, 2007, 0(5): 34-35
Authors:YUAN Li-jun  LI Hua-ming  HU Xing-wei
Affiliation:The measuring room for experiment of power supply department, Tiefa Coal Industry Group Corporation Limited, DiaoBingShan dry of LiaoNing Province 112700
Abstract:The feasibility about using the CL3601 AC-DC type instrument to measure the level 0.2 and below voltage,current,Power Meter is discussed particularly,Which is used by design procedures and test methods and math model and test data.