首页 | 本学科首页   官方微博 | 高级检索  
     

1000MW机组磨煤机超导自启闭式防爆门误动原因及处理
引用本文:彭荣刚,石伟,艾忠岩. 1000MW机组磨煤机超导自启闭式防爆门误动原因及处理[J]. 东北电力技术, 2012, 33(1): 29-31
作者姓名:彭荣刚  石伟  艾忠岩
作者单位:神华国华绥中发电有限责任公司,辽宁 葫芦岛,125222
摘    要:针对绥中发电有限责任公司2×1 000 MW机组磨煤机新式防爆门误动的问题,着重分析了新式防爆门误动等问题的原因,并提出了对防爆门结构和防爆门实验过程的改进措施。

关 键 词:超超临界火电机组  超导自启闭式防爆门  制粉系统  误动

The Cause and Treatment of Malfunction for Superconductive Self-closing Explosion Door in 1 000 MW Units
PENG Rong-gang , SHI Wei , AI Zhong-yan. The Cause and Treatment of Malfunction for Superconductive Self-closing Explosion Door in 1 000 MW Units[J]. Northeast Electric Power Technology, 2012, 33(1): 29-31
Authors:PENG Rong-gang    SHI Wei    AI Zhong-yan
Affiliation:(Shenhua Guohua Suizhong Power Co.,Ltd,Huludao,Liaoning 125222,China)
Abstract:Based on new explosion door malfunction of Suizong 2×1 000 MW coal pulverizer,this paper analyzes the causes of new explosion door malfunction,and proposes improvement measures for the structure and experiment procedure.
Keywords:Ultra supercritical units  Superconductive self-closing explosion door  coal pulverizing system  malfunction