首页 | 本学科首页   官方微博 | 高级检索  
     

大型直流电机采用短路法无火花换向区域的测定试验及分析
引用本文:盛君. 大型直流电机采用短路法无火花换向区域的测定试验及分析[J]. 防爆电机, 2006, 41(5): 40-42
作者姓名:盛君
作者单位:哈尔滨电机厂有限责任公司,黑龙江,哈尔滨,150040
摘    要:阐述了大型直流电机不能采用GB1311-89介绍的四种短路加载方式时,采用西门子短路法进行无火花换向区域的测定试验,经多年实践证明是安全可靠的.

关 键 词:换向  无火花区域试验  电压负反馈短路法
文章编号:1008-7281(2006)05-0040-03
收稿时间:2005-12-03
修稿时间:2005-12-03

Determination Test and Analysis of Non-Sparkling Commutation Area of Large-Sized D. C. Electric Machine by Short-Circuited Method
Sheng Jun. Determination Test and Analysis of Non-Sparkling Commutation Area of Large-Sized D. C. Electric Machine by Short-Circuited Method[J]. Explosion-proof Electric Machine, 2006, 41(5): 40-42
Authors:Sheng Jun
Abstract:This paper describes that the determination test of non-sparkling commu- ration area by short-circuited method of Siemens due to the short-circuited loading method in GB 1311-1989 not being applied to large-sized d. c. electric machine. It is proved that the determination test is safe and reliable by practice.
Keywords:Comonutation  non-sparking negative feedback. area test   short-circuited method of voltage
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号