首页 | 本学科首页   官方微博 | 高级检索  
     

Fenton试剂预处理亚麻生产废水
引用本文:刘娟娟,司洪亮.Fenton试剂预处理亚麻生产废水[J].工业用水与废水,2010,41(5).
作者姓名:刘娟娟  司洪亮
摘    要:采用Fenton试剂预处理亚麻生产废水。探讨了pH值、反应时间、H2O2投加量、FeSO4.7H2O投加量对去除CODCr的影响。试验结果表明:在pH值为4.5,反应时间为60 min,H2O2投加量为5 mL/L,FeSO4.7H2O投加量为1 500 mg/L,H2O2的投加为分批次的连续投加方式时,CODCr去除率为45%,m(BOD5)/m(CODCr)由0.21提高到0.53,出水中检测不到SS的存在,为后续生化处理创造了有利条件。

关 键 词:Fenton  预处理  亚麻废水  正交试验  可生化性

Pretreatment of wastewater from flax production by Fenton reagent
LIU Juan-juan,SI Hong-liang.Pretreatment of wastewater from flax production by Fenton reagent[J].Industrial Water & Wastewater,2010,41(5).
Authors:LIU Juan-juan  SI Hong-liang
Abstract:Fenton reagent was used to pretreat wastewater from flax production.The influences of pH value,reaction time,H2O2 dosage and FeSO4.7H2O dosage on CODCr removal were investigated.The results of the test showed that: under the condition that,the pH value was 4.5,the reaction time was 60 min,the dosage of H2O2 and FeSO4.7H2O were 5 mL / L and 1 500 mg / L respectively,the H2O2 was added to the reactor batch by batch continuously,the removal rate of CODCr reached 45%,the m(BOD5) / m(CODCr) of the wastewater increased from 0.21 to 0.53,and no SS was detected in the effluent water,which provided favorable conditions for the subsequent biochemical treatment.
Keywords:Fenton  pretreatment  wastewater from flax production  orthogonal test  biodegradability
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏