首页 | 本学科首页   官方微博 | 高级检索  
     

某电厂循环水事故停泵关阀瞬变流的仿真研究
作者姓名:江新耀
作者单位:湖北省电力勘测设计院,湖北武汉,430040
摘    要:针对某火力发电厂循环水供水系统的特点,应用一维流体分析软件Flowmaster7对电厂循环水系统进行仿真建模,介绍了电厂主要的循环水构筑物的模型简化及建立依据。对各种事故停泵工况下不同关阀规律对应的瞬变流过程进行了仿真研究,得出了该工况较理想的关阀操作规律。结果表明,关阀瞬变流最大升压出现在2泵同时事故停泵时的工况,且合理的关阀对升压减小、保证凝汽器流量及压力变化合理有着重要的作用。

关 键 词:火力发电厂  循环水  瞬变流  事故关阀  水锤

Simulation of transient flow of accidental pump termination and valve closing in water circulation system of power plant
Authors:Jiang Xinyao
Affiliation:Jiang Xinyao ( Hubei Electric Power Survey & Design Institute, Wuhan 430040, China)
Abstract:According to the characteristics of circulation water supply system in power plant, the model simplification and basis of establishment for main structures of water circulation system in the power plant were introduced by adopting one-dimensional fluid analysis software Flowmaster 7 which could simulate water circulation system of power plant. The transient flow course of different valve closing regularity was simulated under working condition of pump termination, the satisfactory valve closing operation regularity was obtained. The results showed that the maximum pressure rise of transient flow occurred under working condition of two-pump termination at the same time, and it had significant function of reduction of pressure rise, condenser flow ensurance and reasonable pressure variation.
Keywords:power plant  circulation water  transient flow  accidental valve closing  water hammer
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号