高土壤电阻率变电站的降阻探讨
引用本文:柯荷秀. 高土壤电阻率变电站的降阻探讨[J]. 浙江电力, 2012, 0(11): 14-16
作者姓名:柯荷秀
作者单位:杭州市电力设计院,杭州310014
摘    要:针对高土壤电阻率的接地网,根据变电站现场实际情况,采取外延接地体、扩大外延接地网、换入低电阻率土壤等综合降阻措施来降低接地电阻,这样既有效又经济,校核了接地电阻偏高接地网的接触电压和跨步电压。

关 键 词:变电站  高土壤电阻率  接地电阻  降阻

Investigation on Resistance-reduction in Substation with High Earth Resistivity
KE He-xiu. Investigation on Resistance-reduction in Substation with High Earth Resistivity[J]. Zhejiang Electric Power, 2012, 0(11): 14-16
Authors:KE He-xiu
Affiliation:KE He-xiu (Hangzhou Electric Power Design Institute, Hangzhou 310014, China)
Abstract:In accordance with grounding grid with high earth resistivity and practical situation of substation, comprehensive measures such as extension of ground body, expansion of extended grounding grid and replacement by low-resistivity earth are taken to lower ground resistance, which is effective and efficient and verifies high grounding resistance, touch voltage and step voltage.
Keywords:substation  high earth resistivity  ground resistance  resistance reduction