RE-ENTRAINMENT OF DUSTS FROM THE DUST LAYER ON THE THE DEPOSITED DUSTS IN THE CYCLONE DUST COLLECTORS |
| |
Authors: | Akira Ogawa |
| |
Affiliation: |
a Department of Mechanical Engineering, College of Engineering, Nihon University, Japan |
| |
Abstract: | There were many papers concerning the experimental results of the collection efficiency, but up to this time there are a few papers concerning the experimental results of the re-entrainment or dispersion of the dust particles from the dust layer by the turbulent rotational air flow in the dust bunker for the cyclone dust collector. Then in this paper, the author described the experimental results of the re-entrainment of the test dust ( talc XR50 = 8.O µm ) for the four kinds of the throat diameter D3 = 50, 80, 100 and 150 mm. Especially it is very importance to take into consideration of flow rate Qb into the dust bunker which is a function of D3 and cyclone diameter D1 and the maximum tangential velocity Vet in the dust bunker which depends on D1,D3 and Qb. |
| |
Keywords: | |
本文献已被 InformaWorld 等数据库收录! |
|