摘    要:直流系统是十分重要的电源系统,它是一个独立的电源,并且不受发电机、厂用电以及系统运行方式改变的影响。同时继电保护、控制、信号、计算机监控、通讯、断路器操作电源、事故照明等对供电可靠性要求较高,因此直流系统的用电负荷极为重要。

关 键 词:直流系统接地  故障分析  故障处理  注意事项

Analysis and management for grounding fault in DC system
Wang Baochen.Analysis and management for grounding fault in DC system[J].Guizhou Electric Power Technology,2013(12):74-75.
Authors:Wang Baochen
Affiliation:Wang Baochen (Guizhou Wujiangdu Hydropower Development Co., Ltd, Guiyang 550000 Guizhou, China)
Abstract:DC system was a very important power supply system. It had an independent power source, which was not affected by generator, auxiliary power and system operation mode. The requirement on relay protection, control, signal, computer monitoring, commu- nication, breaker operation and emergency lighting was higher, thus the electric load of DC system was particularly important.
Keywords:DC system grounding  fault analysis  fault management  points for attention