Analysis of grounding fault on the AC side of converter station in a flexible DC distribution system
ZHOU Yongrong,QIN Wenkang,GE Jiasheng,SUN Jun,XU Xidong,DONG Rongsen.Analysis of grounding fault on the AC side of converter station in a flexible DC distribution system[J].Power System Protection and Control,2020,48(19):160-167.
Authors:ZHOU Yongrong  QIN Wenkang  GE Jiasheng  SUN Jun  XU Xidong  DONG Rongsen
Affiliation:1. State Grid Electric Power Research Institute Jiangsu Co., Ltd., Nanjing 211106, China; 2. State Key Laboratory of Smart Grid Protection and Operational Control, Nanjing 211167, China; 3. College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
Abstract:In the flexible DC distribution power system, if the converter station is connected to the AC grid via a connecting transformer, the insulation damage between the connecting transformer and the converter valves will cause a grounded fault on the AC side of the converter station. The influence of this grounded fault and the protection strategy is worth researching. First, the equivalent common-mode circuit model of the components in the flexible DC distribution power system is analyzed. Subsequently, the equivalent common-mode circuit model of a flexible five-terminal DC distribution power system with different grounding methods is built. The calculation formulas of fault fundamental frequency common-mode current and voltage after a converter AC side single-phase grounded fault occurs are obtained. Then, considering various resonances that may exist in a DC system, a protection strategy based on a converter DC side fundamental frequency common-mode voltage, current and power direction to identify the single-phase grounded fault on the converter AC side is proposed and verified on the PSCAD platform. This work is supported by National Key Research and Development Program of China (No. 2017YFB0903100).
Keywords:flexible DC distribution power system  grounding method  AC side single-phase grounded fault  common-mode current  common-mode voltage