首页 | 本学科首页   官方微博 | 高级检索  
     


Capacity and Sizing of Wire Mesh Mist Eliminators at Critical Fluid Properties
Authors:Felix Flegiel  Christoph Windmeier  Michael Wiezorek  Alexander Döß  Markus Schubert  Uwe Hampel  Eckhard Schleicher
Affiliation:1. Linde GmbH, Linde Engineering, Dr.-Carl-von-Linde-Straße 6–14, 82049 Pullach, Germany;2. Helmholtz-Zentrum Dresden-Rossendorf e.V., Institute of Fluid Dynamics, Bautzner Landstraße 400, 01328 Dresden, Germany;3. HZDR Innovation GmbH, Bautzner Landstraße 400, 01328 Dresden, Germany
Abstract:Wire mesh flooding point measurements at low surface tension < 10 mN m−1 were conducted using a refrigerant as model fluid. A new method for the calculation of wire mesh capacity was developed based on experimental data from literature and data from this study. In comparison to the well-known and widely adapted K-value method given in the Gas Processors Suppliers Association (GPSA) Engineering Databook and various other sources, the new method yields 3–38 % reduced wire mesh cross sections for fluid systems at pressures above 20 bar(a) while retaining an inherent safety margin.
Keywords:Flooding point  K-value  Mist eliminator capacity  Wire mesh
设为首页 | 免责声明 | 关于勤云 | 加入收藏