首页 | 本学科首页   官方微博 | 高级检索  
     

600MW锅炉加装吹灰器的节能分析
作者单位:北京国华电力技术研究中心 北京065201(李英,王宝良,王强),广东国华台山发电厂 广东江门529200(蔡国权)
摘    要:国华电力公司600 MW锅炉燃用易结渣的神华煤出现过热器区域结渣,不利于传热,造成主汽温偏低和排烟温度偏高,影响机组的经济性和安全稳定运行。分析了结渣原因,对比加装锅炉吹灰器前后,进行了节能分析。

关 键 词:吹灰器  改造  节能

Energy-saving Analysis on Installation of Soot Blower in 600 MW Boiler
Li Ying,Wang Bao-liang,Wang Qiang,Cai Guo-quan. Energy-saving Analysis on Installation of Soot Blower in 600 MW Boiler[J]. North China Electric Power, 2008, 0(5)
Authors:Li Ying  Wang Bao-liang  Wang Qiang  Cai Guo-quan
Affiliation:Li Ying1,Wang Bao-liang1,Wang Qiang1,Cai Guo-quan2
Abstract:Slagging could happen in area of superheater in 600 MW boilers in Guohua Electric Company when firing Shenhua Coal which is clinkering.Such slagging is harmful for heat transferring which caused lower main steam temperature and higher discharge flue temperature and could influence economy and safety operation of units.Slagging causes were analyzed in this paper and energy-saving analysis was given before and after installation of soot blower.
Keywords:soot blower  renovation  energy-saving