Cathodic protection monitoring of buried carbon steel pipeline: measurement and interpretation of instant-off potential
Authors:Andrea Brenna  Silvia Beretta  Riccardo Uglietti  Luciano Lazzari  MariaPia Pedeferri  Marco Ormellese
Affiliation:Dipartimento di Chimica, Materiali e Ingegneria Chimica “Giulio Natta”, Politecnico di Milano, Milano, Italy
Abstract:The criterion used to verify the cathodic protection condition of a structure is based on structure-to-electrolyte potential measurement, which can include an ohmic drop contribution. Among the available techniques, the use of potential probes with internal reference electrode and of corrosion coupons with a so-called soil-access tube represents the most appropriate way to measure the IR-free potential, eliminating the ohmic drop contribution. An alternative is represented by on-off technique if equalising, galvanic or stray currents are not present. Laboratory tests have been carried out in soil-simulating solution on cathodically protected carbon steel in order to evaluate the effectiveness of off-potential for the assessment of cathodic protection. Instant-off potential is not reliable in overprotection condition; moreover, the accuracy of the measurement is strongly influenced by the presence of external current as galvanic or equalising currents. The effect of low-pass filter in the data acquisition system on the potential reading is discussed.
Keywords:Carbon steel  cathodic protection  monitoring  protection potential  ohmic drop  hydrogen overvoltage  instant-off potential