首页 | 本学科首页   官方微博 | 高级检索  
     

基于有限元分析的增湿塔设计校核与应力评定
引用本文:范琦,金如聪. 基于有限元分析的增湿塔设计校核与应力评定[J]. 水泥工程, 2012, 0(6): 42-45
作者姓名:范琦  金如聪
作者单位:1. 北京凯盛建材科技有限公司,北京,100024
2. 南京竣业过程机械设备有限公司,江苏南京,210002
摘    要:将分析设计直接法引入5000t/d生产线的增湿塔设计中,运用有限元分析方法对增湿塔结构进行校核和评定。结合实例,详细阐述了应用有限元软件ANSYS分析增湿塔在不同工况的应力和变形的方法,并对设备最大应力点及其它危险部位进行应力评定。有限元分析法可对同类结构进行分析校核和优化设计。

关 键 词:增湿塔  有限元  ANSYS  地震载荷  风载荷  评定

Design check and stress evaluation of conditioning tower based on finite element analysis
Affiliation:Fan Qi(Beijing Triumph Building Materials Engineering Co.,Ltd Beijing 100024, China)
Abstract:The design based on analysis direct method is introduced into the conditioning tower design.The conditioning tower structure is checked and evaluated based on the finite element analysis method in the paper. Combined with real example,the method of stress and deformation analysis of conditioning tower in different condition by FEA software ANSYS was introduced,and maximum stress point, and other dangerous sites are evaluated. For the same kind of structure,finite element analysis method can be used to analyse check stress and optimize design.
Keywords:conditioning tower  finite element  ANSYS  seismic load  wind load  strength evaluation
本文献已被 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号