首页 | 本学科首页   官方微博 | 高级检索  
     

掩蔽锶-铬酸钡-碘量法测定碳酸锶中钡
引用本文:吴卫东.掩蔽锶-铬酸钡-碘量法测定碳酸锶中钡[J].无机盐工业,2000,32(5):45-46.
作者姓名:吴卫东
作者单位:南京红焰锶业有限公司,南京,211200
摘    要:采用乙二胺四乙酸二钠掩蔽锶,在PH值为5.9条件下,钡离子重铬酸钾生成铬酸钡沉淀,分离后,用碘量法测定。相对标准偏差1.02%-2.17%,加标回收率95%-103%。

关 键 词:EDTA  铬酸钡  碘量法  碳酸锶    掩蔽锶
修稿时间:2000-03-28

DETERMINATION OF BARIUM IN STRONTIUM CARBONATE BY EDTA MASK-BARIUM CHROMATE-IODIMETRY
WU Weidong.DETERMINATION OF BARIUM IN STRONTIUM CARBONATE BY EDTA MASK-BARIUM CHROMATE-IODIMETRY[J].Inorganic Chemicals Industry,2000,32(5):45-46.
Authors:WU Weidong
Abstract:A method for the determination of barium in strontium carbonate is introduced. It masks strontium with EDTA. In a medium of NaOAc - HO Ac buffer solution at pH 5. 9,Ba ( I ) reacts with potassium dichromate to form barium chro-mate precipitate. After separation, it is determined by iodimetry. The RSD obtained is between 1. 02%-2. 17% and the recovery rate is in the range of 95%-103%.
Keywords:EDTA mask5 barium chromate  iodimetry  barium