摘    要:文章从超临界机组的发展趋势,阐述了直流锅炉启动系统的结构和对疏水的处理方式,及将启动疏水回收至除氧器的作用。进而对除氧器用锅炉启动疏水消能装置的研制和应用作了扼要的介绍。

关 键 词:除氧器  超临界  启动  系统  高能疏水  消能装置

Development&Application of Built-in Drainage Equipment in Deaerator Started up with Boiler
LI Yan.Development&Application of Built-in Drainage Equipment in Deaerator Started up with Boiler[J].Power Station Auxiliary Equipment,2009,30(1):8-12.
Authors:LI Yan
Affiliation:LI Yan(Shanghai Power Station Auxiliary Equipment Works,ShanghaiElectric Power Generation Equip.Co.,Ltd,Shanghai,200090,China)
Abstract:The structure of starting-up system for once-through boiler and its handling way against drain have been described in the paper based on the developing trend of supercritical power unit.The development and application of drain energy-relief device for deaerator started up by boiler have briefly been introduced.