低温再热器鼓包分析
引用本文:叶建锋,袁重,陶彦. 低温再热器鼓包分析[J]. 湖北电力, 2012, 36(1): 46-47
作者姓名:叶建锋  袁重  陶彦
作者单位:湖北省电力公司电力试验研究院,武汉,430077
摘    要:某电厂的300MW锅炉大修时发现低温再热器蛇形管多处鼓包。通过宏观检查、金相分析,结果表明,低温再热器烟温过高以及低温再热器弯头制造工艺不当导致弯头局部短时超温,从而出现鼓包。

关 键 词:锅炉  低温再热器  短时超温

Analysis of Bloating Behavior of Low-temperature Reheater in Power Plant Boiler
YE Jian-feng , YUAN Zhong , TAO Yan. Analysis of Bloating Behavior of Low-temperature Reheater in Power Plant Boiler[J]. Hubei Electric Power, 2012, 36(1): 46-47
Authors:YE Jian-feng    YUAN Zhong    TAO Yan
Affiliation:(Electric Testing & Research Institute of Hubei EPC,Wuhan Hubei 430077,China)
Abstract:During Overhaul in Hubei power plant,the bloatings of s-tubes of low-temperature reheater were found and the cause of bloating was analyzed by macroscopic inspection and metallographic analysis.The results indicated that the short term super-high temperature phenomenon was mainly caused by high-temperature operation of flue gas and improper manufacturing technology of elbow and thus produced bloatings.
Keywords:boiler  low-temperature reheater  momentary overheating