摘    要:通过对嵩屿电厂 28台主要辅机 1996-1998年非计划停运次数的统计、归类和比较,分析影响主要辅机可靠性因素,总结发生非计划停运的设备部件、技术原因和责任原因,对存在的问题及进一步提高主要辅机可靠性水平提出建议。

关 键 词:辅机 可靠性 非计划停运 可用系数 电厂

Reliability Analysis of Main Auxiliaries in Songyu Thermal Power Plant
CHEN Lin zhong. Reliability Analysis of Main Auxiliaries in Songyu Thermal Power Plant[J]. Electric Power, 2000, 33(5): 73-76,88
Authors:CHEN Lin zhong
Affiliation:CHEN Lin-zhong
Abstract:Through the statistics, classification and comparison of unplanned outages of 28 sets main auxiliaries in 1996-1998 in Songyu Thermal Power Plant, the factors influencing the reliability of main auxiliaries are analyzed, the parts of equipment suffering from, and technical and responsibility causes for unplanned outages are summarized, and finally, the existing problems and the proposals for further improving the reliability level of main auxiliaries are put forward.
Keywords:main auxiliaries  reliability  unplanned outage  availability factor  