首页 | 本学科首页   官方微博 | 高级检索  
     


Failure Investigation of Cracks in Bolted Flange
Authors:Gys van Zyl  Mazin Al-Musharraf  Mohammed Al-Muaisub
Affiliation:1. SABIC Manufacturing Competence Center, Jubail, Saudi Arabia
Abstract:Cracks were observed on the outer diameter of the bolted flanges of a number of large control valves in high temperature service. An investigation was launched to determine the cause of cracking and propose corrective action. Metallurgical failure analysis and finite element analysis techniques were used to investigate the fracture, and concluded that the failures occurred due to thermal fatigue. A structural assessment performed on a cracked flange concluded that the cracks do not have an adverse effect on the integrity of the flange and it was concluded that the cracked flanges could be safely returned to service.
Keywords:
本文献已被 SpringerLink 等数据库收录!