摘    要:通过对华能南通电厂350MW机组汽动给水泵连续5次解体故障原因的详细分析,指出设备结构、检修工艺和运行操作等方面存在的问题,并进一步从运行和检修2方面提出改进和防洪措施及其实施效果。通过改造,汽动给水泵的故障发生率大大降低

关 键 词:锅炉 给水泵 故障分析
修稿时间:1999-12-17

Measures to Reduce Faults of Boiler Feedwater Pump
GAO Li-hua,XU FANG. Measures to Reduce Faults of Boiler Feedwater Pump[J]. Electric Power, 2000, 33(5): 37-39
Authors:GAO Li-hua  XU FANG
Affiliation:GAO Li-hua XU FAN
Abstract:There are two 350 MW generating units instralled in Huaneng Nantong Thermal Power Plant.Through five times successive dismantlements and detail analyses of causes for faults of steam turbine-driven feedwater pumps,the problems existing in equipment configuration. repairing technology, and operation etc,Aspects were found out,and thereby the improvement proposals on operation and repair and preventive measures were further put forward.Through retrofit, the fault occurrence rate of steam turbine-driven feedwater pumps has been greatly reduced.
Keywords:boiler feedwater pump  fault analysis: improvement measures