Design Criteria for Cost-Effective Broad-Band Absorber-Lined Chambers for EMS Measurements |
| |
Authors: | Mishra S.R. Pavlasek T.J.F. Yazar M.N. |
| |
Affiliation: | Electrical Engineering Departmnent, McGill University, 817 Sherbrooke St. W., Montreal, PQ H3A 2K6, Canada. (514) 392-5879; |
| |
Abstract: | The problem considered here concerns simulating the electromagnetic environment for electromagnetic susceptibility (EMS) measurements over a wide frequency range. Means of bridging the existing gap between low-and high-frequency techniques are suggested by extending the use of anechoic-type chambers downward in frequency. Results of measurements over a wide frequency range are presented to demonstrate the behavior of such absorber-lined chambers (ALC's). Basic criteria and guidelines for the design of ALC's are proposed. |
| |
Keywords: | |
|
|