首页 | 本学科首页   官方微博 | 高级检索  
     


The influence of the coordinate errors of setting sensors of a piezoelectric antenna on the accuracy of localizing sources of acoustic-emission signals
Authors:A. E. Kareev  L. N. Stepanova  E. S. Tenitilov
Affiliation:1.OOO Parallels-Novosibirsk,Novosibirsk,Russia;2.Chaplygin Siberian Research Institute of Aviation,Novosibirsk,Russia
Abstract:The main factors that affect the error of determining the coordinates of an acoustic-emission (AE) signal source are considered. The influence of errors of determining coordinates ±Δx i and ±Δy i of piezoelectric-antenna transducers on the AE-signal localization accuracy are analyzed. It is theoretically and experimentally proven that the errors in the coordinates of the transducers substantially influence the AE-signal localization accuracy, especially at a low sampling frequency of the analog-to-digital converter of the AE system’s measuring channel and when low-frequency AE transducers are used.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏