摘    要:针对蓄热式轧钢加热炉在生产中由于操作不当而造成升温慢、空燃比配合不当和能耗高的问题,总结出一套“三协调”操作法。介绍了该操作法的主要理论根据和实际操作要领,以及取得的较好效果。

关 键 词:蓄热式加热炉  操作法  应用效果
文章编号:1003-9996(2006)02-0065-02
收稿时间:2005-09-05
修稿时间:2005-10-19

Coordination Operation Method for Three Group Parameters of Regenerative Heating Furnace
LUO Guo-min,ZHANG Shao-zhong. Coordination Operation Method for Three Group Parameters of Regenerative Heating Furnace[J]. Steel Rolling, 2006, 23(2): 65-66
Authors:LUO Guo-min  ZHANG Shao-zhong
Abstract:A coordination operation method for three group parameters of regenerative heating furnace was summarized.The problems of slow heating,unreasonable rate of air and gases and high energy consumption by malfunction operation were overcome.The main theory and operation key points of this method were introduced.