首页 | 本学科首页   官方微博 | 高级检索  
     

国产PVA纤维混凝土早期抗裂性能试验研究
引用本文:安嘉伟,赵建军,刘曙光,闫长旺,徐勇彪. 国产PVA纤维混凝土早期抗裂性能试验研究[J]. 混凝土, 2020, 0(2): 154-157. DOI: 10.3969/j.issn.1002-3550.2020.02.034
作者姓名:安嘉伟  赵建军  刘曙光  闫长旺  徐勇彪
作者单位:内蒙古工业大学 土木工程学院,内蒙古 呼和浩特 010051;内蒙古工业大学 土木工程学院,内蒙古 呼和浩特 010051;内蒙古工业大学 矿业学院,内蒙古 呼和浩特 010051;内蒙古双欣环保材料股份有限公司,内蒙古 鄂尔多斯 016062
摘    要:为了研究聚乙烯醇(PVA)纤维对混凝土早期抗裂性能的影响。制作了7组混凝土平板早期抗裂试验,其中6组混凝土里面掺入了PVA纤维,观察记录了开裂的整个过程。纤维长度和体积掺量为主要研究对象。通过计算得出了单位面积下不同配合比混凝土的裂缝总条数以及总面积,而且对混凝土裂缝降低系数进行了对比分析。试验结果表明:掺入纤维后,混凝土的早期抗裂性能有明显提高,不仅裂缝宽度有所减小,而且裂缝数量也有所减少。其中纤维长度为12 mm、体积掺量为1.6 kg/m^3的混凝土早期抗裂性能改善能力最明显,可以为PVA纤维在工程中的应用提供参考依据。

关 键 词:PVA纤维混凝土  早期抗裂  纤维长度  纤维体积掺量

Experimental study on early crack resistance of domestic PVA fiber concrete
AN Jiawei,ZHAO Jianjun,LIU Shuguang,YAN Changwang,XU Yongbiao. Experimental study on early crack resistance of domestic PVA fiber concrete[J]. Concrete, 2020, 0(2): 154-157. DOI: 10.3969/j.issn.1002-3550.2020.02.034
Authors:AN Jiawei  ZHAO Jianjun  LIU Shuguang  YAN Changwang  XU Yongbiao
Affiliation:(School of Civil Engineering,Inner Mongolia University of Technology,Hohhot 010051,China;Institute of Mining Technology,Inner Mongolia University of Technology,Hohhot 010051,China;Inner Mongolia Shuang-xin Environmental Protection Material Limited by Share Ltd.,Ordos 016062,China)
Abstract:In order to study the effect of polyvinyl alcohol(PVA)fiber on the early crack resistance of concrete.Seven sets of concrete flat crack test were made,in which 6 sets of concrete were mixed with PVA fiber,and the whole process of cracking was observed.Fiber length and volume content are the main research objects.Through calculation,the total number of cracks and total area of concrete with different proportions under unit area were obtained,and the concrete crack reduction coefficient was compared and analyzed.The test results show that the early crack resistance of the concrete is obviously improved after the fiber is blended,not only the crack width is reduced,but also the number of cracks is reduced.Among them,the early crack resistance performance of concrete with fiber length of 12 mm and volume of 1.6 kg/m^3 is the most obvious,which can provide reference for the application of PVA fiber in engineering.
Keywords:PVA fiber concrete  early cracking  fiber length  fiber volume content