洁净实验室空调设计及节能措施探讨 |
| |
引用本文: | 梁晓媚,;杨素云,;王培财. 洁净实验室空调设计及节能措施探讨[J]. 广东土木与建筑, 2009, 0(5): 36-37 |
| |
作者姓名: | 梁晓媚, 杨素云, 王培财 |
| |
作者单位: | [1]广州瀚华建筑设计有限公司,广州510630; [2]广州大学,广州510006; [3]广州金海设计有限公司,广州510040 |
| |
摘 要: | 介绍洁净实验室的空调设计原则,结合工程实例介绍风量平衡计算和系统设备选型设计,并探讨空气处理机组变风量运行、减少风机温升负荷、限制新风量和设计风机压头等多项节能措施。
|
关 键 词: | 洁净实验室 空调设计 节能 |
Discussion on Air-conditioning Design for Clean Room and Energy-saving Methods |
| |
Affiliation: | Liang Xiaomei,Yang Suyun,Wang Peicai ( 1. Guangzhou Hanhua Architectural Design Co., Ltd Guangzhou 510630, China; 2.Guangzhou University Guangzhou 510006,China; 3.Guangzhou Jinhai Architectural Design Co.,Ltd Guangzhou 510040,China) |
| |
Abstract: | This paper introduces the codes about air-conditioning design for clean room,practical project is put to prove the calculation of air volume balance and selection of air-conditioning equipments. In the end,four solutions are listed for energy-saving methods,which are nmning of variable air volume system,lowering the load of fan temperature,the restriction of fresh air, moreover the head design of ventilation equipment. |
| |
Keywords: | clean room air-conditioning design energy-saving |
本文献已被 维普 等数据库收录! |
|