摘    要:文章结合《煤矿安全规程》和现场经验,分析了煤矿井下掘进工作面串掘进工作面、采煤工作面串掘进工作面、掘进工作面串采煤工作面3种串联通风方式下局扇监控自动断电存在的问题及采取的相应解决方案,并给出了详细图解。这些解决方案对实际工作具有一定的参考作用。

关 键 词:煤矿  局扇  串联通风  安全监控  自动断电

Solutions of Automatic Power-off of Local Fan Monitoring
HUANG Wei. Solutions of Automatic Power-off of Local Fan Monitoring[J]. Industry and Automation, 2009, 35(9)
Authors:HUANG Wei
Affiliation:Monitoring Information Team of Xieyi Coal Mine of Huainan Coal Mining Group;Huainan 232052;China
Abstract:The paper analyzed existing problems of automatic power-off of local fan monitoring in three kinds of series ventilation mode of tunneling face series tunneling face,coal face series tunneling face,tunneling face series coal face and adopted corresponding solutions,and gave detailed graphic.These solutions have the certain reference function for actual work.
Keywords:coal mine  local fan  series ventilation  safety monitoring  automatic power-off  