首页 | 本学科首页   官方微博 | 高级检索  
     

600MW汽轮机组高调门故障引发机组跳闸的分析与处理
引用本文:丁成国. 600MW汽轮机组高调门故障引发机组跳闸的分析与处理[J]. 贵州电力技术, 2012, 0(11): 12-14
作者姓名:丁成国
作者单位:平圩发电有限责任公司,安徽淮南232000
摘    要:某电厂一台600MW汽轮机组在运行状态下,因为卸荷阀泄漏造成高调门CV2全关,引发机组跳闸,通过对事件的过程处理及原因分析,制定了主汽门故障的应对及处理措施。

关 键 词:600  MW机组  汽轮机  高压调门  跳闸  处理措施

Analysis and solution of unit trip by 600 MW steam turbine high pressure valve fault
Ding Chengguo. Analysis and solution of unit trip by 600 MW steam turbine high pressure valve fault[J]. Guizhou Electric Power Technology, 2012, 0(11): 12-14
Authors:Ding Chengguo
Affiliation:Ding Chengguo (Pingxu Power Generation Co. , Ltd, Huainan 232000 Anhui ,China)
Abstract:Because of that relief valve leaking made all high pressure valve GV2 close, a 600 MW steam turbine unit trip in the running state. Through studying the process and the reasons, made a handling measures for the main valve fault.
Keywords:600 MW unit  steam turbine  high pressure valve  trip, measures
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号