首页 | 本学科首页   官方微博 | 高级检索  
     

负载不对称H桥级联APF直流电压平衡控制
引用本文:刘亚云,梁平,刘心漪,黄海宏.负载不对称H桥级联APF直流电压平衡控制[J].电子测量与仪器学报,2016,30(7):1127-1135.
作者姓名:刘亚云  梁平  刘心漪  黄海宏
作者单位:1. 合肥工业大学电气与自动化工程学院合肥 230009;2. 合肥工业大学机械工程学院合肥 230009
基金项目:国家自然科学基金(51177037)
摘    要:H桥级联型有源电力滤波器(APF)在高压场合的谐波处理方面具有广阔的应用前景。三相三线制系统下负载不对称时,APF输出的基波电压和电流产生不同的有功分量分配至三相,再加上H桥各个模块的差异等原因,导致直流侧电压不均衡,影响APF的正常运行。通过对级联APF功率模型的推导,控制APF输出基波正序有功电流稳定全局电压、输出基波负序电流实现三相之间电压均衡。在全局稳压和相间均压条件下,控制各H桥交流侧输出补偿有功电压矢量实现相内电压均衡,最终将每个H桥直流电压维持在给定值附近,同时APF补偿谐波电流,降低网侧电流THD。在低压条件下的仿真和实验结果验证了所用方法的可行性,为级联APF向更高电压等级场合的应用提供了基础。

关 键 词:三相三线制  负载不对称  基波正序有功电流  基波负序电流  有功电压矢量

DC voltage balance control for cascaded H bridge APF with unbalanced loads
Liu Yayun,Liang Ping,Liu Xinyi and Huang Haihong.DC voltage balance control for cascaded H bridge APF with unbalanced loads[J].Journal of Electronic Measurement and Instrument,2016,30(7):1127-1135.
Authors:Liu Yayun  Liang Ping  Liu Xinyi and Huang Haihong
Affiliation:School of Electrical Engineering and Automation, Hefei University of Technology, Hefei 230009, China,School of Mechanical Engineering, Hefei University of Technology, Hefei 230009, China,School of Electrical Engineering and Automation, Hefei University of Technology, Hefei 230009, China and School of Electrical Engineering and Automation, Hefei University of Technology, Hefei 230009, China
Abstract:The cascaded H-bridge APF (active power filter)has wide application prospect in the field of high voltage harmonic processing.When the load is unbalanced in the three-phase three-wire system,the fundamental wave voltage and current outputted from APF generate different active components and they are assigned to each phase.With the differences between H-bridge modules,the DC side voltages will be unbalanced.It can affect the normal operation of APF.By derivation of the power model of cascaded H-bridge APF,the global voltage stabilization is achieved by controlling the fundamental positive sequence active current and the three-phase voltage balance is achieved by controlling the fundamental negative sequence current outputted from APF.Under these two conditions,the voltage balance in one phase is achieved by controlling the active voltage vector of AC side in each H-Bridge.They control each DC side voltage at a given value eventually.At the same time,the cascaded APF compensates harmonic current and reduces THD of the grid current.The feasibility of the method is verified by simulation and experimental results under low voltage conditions,and it provides the basis for application of the APF to a higher voltage level.
Keywords:three-phase three-wire system  load asymmetry  fundamental positive sequence active current  fundamental negative sequence current  active voltage vector
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《电子测量与仪器学报》浏览原始摘要信息
点击此处可从《电子测量与仪器学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号