首页 | 本学科首页   官方微博 | 高级检索  
     

钢-混凝土组合式风力发电塔架地震响应分析
引用本文:陈俊岭,王大伟,冯又全.钢-混凝土组合式风力发电塔架地震响应分析[J].太阳能学报,2022,43(3):396-404.
作者姓名:陈俊岭  王大伟  冯又全
作者单位:1.同济大学建筑工程系,上海 200092; 2.上海风畅土木工程技术有限公司,上海 200092
基金项目:国家自然科学基金面上项目(51978528);
摘    要:钢-混凝土组合式风力发电塔架上部为钢塔筒,下部为混凝土塔筒,高度方向具有较大的质量和刚度突变,其在地震作用下的响应和传统单管式钢塔架显著不同.利用ABAQUS对同一风电场的2.0 MW单管式钢塔架和组合式塔架建立精细化模型,选取3种场地条件,采用振型分解反应谱法计算2种塔架的地震响应并进行对比.针对3种场地条件,选取相...

关 键 词:风电机组  地震响应  时程分析  谱分析  钢-混凝土组合式塔架
收稿时间:2020-06-15

SEISMIC RESPONSE ANALYSIS OF STEEL-CONCRETE HYBRID WIND TURBINE TOWER
Chen Junling,Wang Dawei,Feng Youquan.SEISMIC RESPONSE ANALYSIS OF STEEL-CONCRETE HYBRID WIND TURBINE TOWER[J].Acta Energiae Solaris Sinica,2022,43(3):396-404.
Authors:Chen Junling  Wang Dawei  Feng Youquan
Affiliation:1. Department of Structural Engineering, Tongji University, Shanghai 200092, China; 2. Shanghai Fengchang Civil Engineering Technology Co., Ltd., Shanghai 200092, China
Abstract:The steel-concrete hybrid wind turbine tower is characterized by the lower part of the traditional steel tube tower replaced with the concrete segment. Because of the mass and stiffness mutation along the height of the tower, its seismic response is significantly different from that of the traditional single-tube steel wind turbine tower. Two detailed finite element models for a single-tube steel tower and a steel-concrete hybrid tower for 2.0 MW wind turbines built in the same wind farm, are developed with ABAQUS. The mode-superposition response spectrum method is applied to calculate and compare the seismic responses of these two towers under three different site conditions. Three groups of ground motions corresponding to three site conditions are used to analyze the dynamic response of the steel-concrete hybrid tower by nonlinear time series analyses. The numerical results show that the mode-superposition response spectrum method is not safe to calculate the seismic response of the steel-concrete hybrid tower directly and the time series analysis should be a necessary supplement in engineering design. The internal force and horizontal displacement responses at the top of the hybrid tower reach their maximums under the medium hard soil site and the soft soil site respectively. The first three modes have obvious contributions on the dynamic response of the steel-concrete hybrid tower. The dynamic response corresponding to the second mode response is the largest contribution, which shows the contributions of higher modes are significant.
Keywords:wind turbines  seismic response  time series analysis  spectrum analysis  steel-concrete hybrid tower  
点击此处可从《太阳能学报》浏览原始摘要信息
点击此处可从《太阳能学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号