首页 | 本学科首页   官方微博 | 高级检索  
     


Measurement Of Indoor Relative Humidity Using A Passive Sampler For Water Vapour
Authors:Peter Norberg  Hans Stymne
Abstract:As part of the energy and indoor climate survey recently carried out in Sweden (the ELIB study) a simple, inexpensive but reliable passive sampler for estimating monthly averages of relative humidity has been developed. The diffusion sampler consists of a 5 ml plastic tube prepared with lithium chloride monohydrate (LiCl. H2O) as trapping medium. After necessary calibration of this particular design of sampler the relative humidity can be calculated from the weight change of the sampler, the time of sampling and the average temperature during this period. The estimated accuracy of the method is better than k 2% RH up to65% RH.
Keywords:Passive sampler  Evaluation tests  Water vapour  Relative humidity  Large-scale survey  Indoor climate
设为首页 | 免责声明 | 关于勤云 | 加入收藏