首页 | 本学科首页   官方微博 | 高级检索  
     


Evaluation of inside surface condensation in double glazing window system with insulation spacer: A case study of residential complex
Authors:Seung-Yeong Song  Jae-Hun Jo  Myoung-Souk Yeo  Young-Don Kim  Kyoo-Dong Song
Affiliation:1. Department of Architecture, Ewha University, 11-1 Daehyun-dong, Seodaemun-gu, Seoul 120-750, Korea;2. Department of Architecture, Seoul National University, Seoul 151-742, Korea;3. School of Architecture, Hanyang University (Ansan), Gyeonggi-do 426-791, Korea
Abstract:Aluminum spacer used to keep the glass panes apart acts as a thermal bridge that increases the risk of inside surface condensation due to its high thermal conductivity. In this study, the inside surface condensation in double glazing window systems with conventional aluminum spacer and insulation spacers made of thermally broken aluminum and thick-walled plastic, respectively, is evaluated. Evaluation method and judgment criteria for preventing inside surface condensation are suggested. Thermal characteristics of window system in residential unit are analyzed and two-dimensional steady state heat transfer simulation is carried out in order to obtain the lowest inside surface temperature. The results show that the application of insulation spacer can substantially increase the lowest inside surface temperature, temperature difference ratio and inside air humidity for preventing inside surface condensation and satisfy the required minimum temperature difference ratio.
Keywords:Double glazing window system   Surface condensation   Insulation spacer   Warm edge technology
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号