某热电厂2DG-10J型给水泵增容改造
引用本文:卞国强,岳勇. 某热电厂2DG-10J型给水泵增容改造[J]. 热力发电, 2006, 35(12): 72-72,77
作者姓名:卞国强  岳勇
作者单位:常州亚能热电有限公司,江苏,常州,213119;江苏省特种设备安全监督检验研究院常州分院,江苏,常州,213002
摘    要:据给水泵运行要求的实际参数,通过计算确定改造参数,并按确定的参数对给水泵进行了增容改造,改造后泵出力接近实际运行工况,节能效果明显。

关 键 词:给水泵  叶轮  扬程  增容改造  热电厂
文章编号:1002-3364(2006)12-0072-01

CAPACITY-INCREASING RETROFIT OF 2DG-10J TYPE FEED-WATER PUMP IN ONE THERMAL POWER PLANT
BIAN Guo-qiang,YUE Yong. CAPACITY-INCREASING RETROFIT OF 2DG-10J TYPE FEED-WATER PUMP IN ONE THERMAL POWER PLANT[J]. Thermal Power Generation, 2006, 35(12): 72-72,77
Authors:BIAN Guo-qiang  YUE Yong
Abstract:Based on practical parameters required in operation of the feed - water pump, the parameters for retrofitting have been determined through calculation, and the capacity - increasing retrofit being carried out according to the determined parameters. After retrofitting, the capacity of the said pump is close to practical operating condition. the effectiveness of energy- saving to be remarkable.
Keywords:feed-water pump  impeller  uplift head  capacity-increasing retrofit  thermal power plant