首页 | 本学科首页   官方微博 | 高级检索  
     

鲁川气体16000m~3/h空分设备不裸冷开车总结
引用本文:刘辉,谢银宇,俞建平.鲁川气体16000m~3/h空分设备不裸冷开车总结[J].深冷技术,2010(5):41-43.
作者姓名:刘辉  谢银宇  俞建平
作者单位:淄博鲁川气体有限公司,山东省淄博市桓台县张店区荆家镇256400
摘    要:介绍空分设备不裸冷开车的前提条件,从空分设备安装现场的管理与监督、安装施工阶段项目管理控制以及开车阶段控制等方面分析了保证空分设备不裸冷开车成功的关键因素,叙述了鲁川气体16000 m3/h空分设备不裸冷开车的具体实施过程。

关 键 词:大型空分设备  不裸冷开车  启动  安装  质量控制

Summary of non-naked cooling start of Luchuan Gas 16000m^3/h air separation plant
Liu Hui,Xie Yinyu,Yu Jianping.Summary of non-naked cooling start of Luchuan Gas 16000m^3/h air separation plant[J].Cryogenic Technology,2010(5):41-43.
Authors:Liu Hui  Xie Yinyu  Yu Jianping
Affiliation:( Zibo Luchuan Gas Co., Ltd., Jingjia Town, Zhangdian District, Huantai County, Zibo 256400, Shandong, P. R. China)
Abstract:Here, the prerequisite conditions for the non-naked cooling start of air separation plant are described, the key factors for successful for non-naked cooling start of air separation plant are analyzed from site management and supervision installation site, project management and control during installation and construction state, and the control at start stage of air separation plant, and the non-naked cooling start process of Luchuan Gas 16000 m^3/h air separation plant is described.
Keywords:Large-sized air separation plant  Non-naked cooling start  Start  Installation  Quality control